Item Brochure

BD Vacutainer
®
Coagulation Tubes (Buffered Sodium Citrate)
BD Vacutainer
®
Citrate tubes are used to obtain a citrate plasma sample. They contain buffered sodium citrate solution, which is used as an antico-
agulant. The tubes are available in a range of sizes in both plastic and glass and can be identified by a light blue cap.
BD Vacutainer
®
Plus Citrate features innovative tube geometry that minimises tube headspace and associated platelet activation to optimise APTT
monitoring of unfractionated Heparin patients. You will always get a full draw with standard outside tube dimensions, even with small draw volumes.
BD Vacutainer
®
Plus Citrate tubes combine the following advantages:
Clinically equivalent performance to the recognised global ‘Gold Standard’, the 4.5ml BD Vacutainer
®
Glass Buffered Citrate tube.
1
Clinically proven in multi-centre clinical trials for coagulation testing across all major patient populations.
Evaluated with the most widely used coagulation analytical systems.
2
BD Vacutainer
®
brand also offers glass CTAD (buffered Citrate, Theophylline, Adenosine and Dipyridamole) tubes to obtain a citrate plasma sample,
where the in vitro heparin activity has been stabilised.
11
Cat. No. NHS Code Vol. (ml) Additive Cap Colour Size (mm) Label Type Box/Case Qty
BD Vacutainer
®
Plus Citrate tube with Light Blue BD Hemogard
TM
Closure
363093 KFK117 1.8 Na Citrate (0.109M) 13x75 Block 100/1000
363095 KFK119 2.7 Na Citrate (0.109M) 13x75 Block 100/1000
BD Vacutainer
®
Glass Citrate tube with Light Blue BD Hemogard
TM
Closure
367691 KFK186 4.5 Na Citrate (0.105M) 13x75 Block 100/1000
BD Vacutainer
®
Glass CTAD tube with Light Blue BD Hemogard
TM
Closure
367562 KFK043 2.7 CTAD (0.109M) 13x75 Paper 100/1000
367595 3.15 CTAD (0.109M) 13x75 Paper 100/1000
367599 KFK022 4.5 CTAD (0.109M) 13x75 Paper 100/1000
1. BD Ref. VS5936 Evaluation of BD Vacutainer
®
Plus 2.7 and 1.8mL Sodium Citrate Coagulation Tubes Using The ELECTRA 1400c™ Analyser. BD, Franklin Lakes, NJ, USA November 2001
2. BD Ref. VS5966 Evaluation of 0.109M BD Vacutainer® Plus Plastic and 0.105M BD Vacutainer
®
Glass Sodium Citrate Tubes for PT and APTT Using the Sysmex CA - 1500 Analyzer. BD, Franklin Lakes, NJ, USA June 2002
Please contact us for copies of BD clinical studies relating to BD Vacutainer
®
Plus Citrate Tubes
Mixing recommendation: Citrate tubes should be gently inverted 180º
and back 3-4 times
Centrifugation Instructions: Plastic Citrate tubes - 2000-2500g for 10-15 minutes at 25ºC room temperature
Glass Citrate tubes - 1500g for 15 minutes at 25ºC room temperature*