Item Brochure

bd.com
References
*
Compared to 96 hours with an open system.
When used with a specially designed 3M
Tegaderm
IV site
securement dressing.
Compared with B. Braun Introcan Safety
®
catheter with Bard Statlock
®
IV Ultra stabilization device.
±
Compared with an FEP catheter.
1. González López J, Arribi Vilela A, Fernández Del Palacio E, et al. Indwell
times, complications and costs of open vs closed safety peripheral
intravenous catheters: a randomized study. J Hosp Infect.
2014;86(2):117-126.
2. Tamura N, Abe S, Hagimoto K, et al. Unfavorable peripheral intravenous
catheter replacements can be reduced using an integrated closed
intravenous catheter system. J Vasc Access. 2014;15(4):257-263.
3. Bausone-Gazda D, Lefaiver CA, Walters SA. A randomized controlled trial
to compare the complications of 2 peripheral intravenous catheter-
stabilization systems. J Infus Nurs. 2010;33(6):371-384.
4. Infusion Nurses Society. Infusion therapy standards of practice.
J Infus Nurs. 2016:39(1S).
5. O’Grady NP, Alexander, M, Burns LA, et al. Guidelines for the prevention
of intravascular catheter-related infections. CDC. 2011:36.
6. Maki DG, Ringer M. Risk factors for infusion-related phlebitis with small
peripheral venous catheters. Annals of Internal Medicine. 1991;
114:845-854.
BD, the BD Logo, MaxZero, Nexiva and Vialon are trademarks of Becton, Dickinson
and Company or its affiliates. © 2020 BD. All rights reserved. BD-20050 (10/20)
BD, Sandy, UT, 84070, USA
BD Nexiva
Closed IV Catheter System - Single Port with BD MaxZero
Needle-free Connector
Catalog No. Gauge
Catheter
Length
(in)
Catheter
ID (mm)
Catheter
OD (mm)
Extension
Tube
Length (in)
Gravity
Flow Rate
(mL/min)
Gravity
Flow Rate
(mL/sec)
Catheter
Priming
Volume
(mL)
Connector
Priming
Volume
(mL)
Maximum Power
Injector Flow Rate
for Contrast Media
@ 22˚C (72˚F)*
Maximum Power
Injector Pressure
Limit Setting
Packaging
(UOM)
383550 24 0.56 0.53 0.71 4.5 19 0.32 0.3 0.16
Not for use with power injectors
20/Box 80/Case
383551 24 0.75 0.53 0.71 4.5 18 0.30 0.3 0.16 20/Box 80/Case
383552 22 1.00 0.67 0.90 4.5 33 0.55 0.3 0.16 3.0 mL/sec
300 psi
(2068 kPa)
20/Box 80/Case
383553 22 1.75 0.67 0.90 4.5 30 0.50 0.3 0.16 3.0 mL/sec 20/Box 80/Case
383556 20 1.00 0.83 1.10 4.5 61 1.02 0.5 0.16 4.0-5.5 mL/sec 20/Box 80/Case
383557 20 1.25 0.83 1.10 4.5 58 0.97 0.5 0.16 4.0-5.5 mL/sec 20/Box 80/Case
383558 20 1.75 0.83 1.10 4.5 51 0.85 0.5 0.16 4.0-5.5 mL/sec 20/Box 80/Case
383559 18 1.25 0.98 1.31 4.5 84 1.40 0.5 0.16 4.0-7.0 mL/sec 20/Box 80/Case
383560 18 1.75 0.98 1.31 4.5 79 1.32 0.5 0.16 4.0-7.0 mL/sec 20/Box 80/Case
BD Nexiva
Closed IV Catheter System - Dual Port with BD MaxZero
Needle-free Connector
Catalog No. Gauge
Catheter
Length
(in)
Catheter
ID (mm)
Catheter
OD (mm)
Extension
Tube
Length (in)
Gravity
Flow Rate
(mL/min)
Gravity
Flow Rate
(mL/sec)
Catheter
Priming
Volume
(mL)
Connector
Priming
Volume
(mL)
Maximum Power
Injector Flow Rate
for Contrast Media
@ 22˚C (72˚F)*
Maximum Power
Injector Pressure
Limit Setting
Packaging
(UOM)
383570 24 0.56 0.53 0.71 4.5 19 0.32 0.4 0.16
Not for use with power injectors
20/Box 80/Case
383571 24 0.75 0.53 0.71 4.5 18 0.30 0.4 0.16 20/Box 80/Case
383572 22 1.00 0.67 0.90 4.5 33 0.55 0.4 0.16 3.0 mL/sec
300 psi
(2068 kPa)
20/Box 80/Case
383573 22 1.75 0.67 0.90 4.5 30 0.50 0.4 0.16 3.0 mL/sec 20/Box 80/Case
383576 20 1.00 0.83 1.10 4.5 61 1.02 0.5 0.16 4.0-5.5 mL/sec 20/Box 80/Case
383577 20 1.25 0.83 1.10 4.5 58 0.97 0.5 0.16 4.0-5.5 mL/sec 20/Box 80/Case
383578 20 1.75 0.83 1.10 4.5 51 0.85 0.5 0.16 4.0-5.5 mL/sec 20/Box 80/Case
383579 18 1.25 0.98 1.31 4.5 84 1.40 0.5 0.16 4.0-7.0 mL/sec 20/Box 80/Case
383580 18 1.75 0.98 1.31 4.5 79 1.32 0.6 0.16 4.0-7.0 mL/sec 20/Box 80/Case
* The BD Nexiva™ Closed IV Catheter System has been tested at the listed flow rates; however, due to variations in add-on devices, tubing, contrast media
temperature and pressure limit settings, these flow rates may not be achievable.
Consult product insert for complete instructions, warnings and cautions.