PROPANE FORCED AIR HEATER operation manual HL060F HL125F
table of contents Safety 6 7 Safety Rules Safety Warnings Features 11 Features Assembly 12 Components 12 Assembling Frame and Wheels Operation 14 14 15 15 16 16 17 17 18 Kerosene (1-K) Theory of Operation Fueling Your Heater Clearances Ventilation Starting the Heater Stopping the Heater Restarting the Heater Long-Term Storage of the Heater Maintenance 19 19 19 20 21 21 22 23 Fuel Tank Fan Blades Nozzle Spark Plug Photocell Fuel Filter Pump Pressure Adjustment Air Bleed Directions Troubleshoot
introduction Attention: Read through the complete manual prior to the initial use of your Compressor Using the Operator’s manual The operating manual is an important part of your Heater and should be read thoroughly before initial use, and referred to often to make sure adequate safety and service concerns are being addressed. Reading the owner’s manual thoroughly will help avoid any personal injury or damage to your heater.
product identification Record Identification Numbers Heater If you need to contact an Authorized Dealer or Customer Service line (1866-770-1711) for information on servicing, always provide the product model and identification numbers. You will need to locate the model and serial number for the heater and record the information in the places provided below.
safety Save these Instructions Safety Rules This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. The safety alert symbol ( ) is used with a signal word (DANGER, CAUTION, WARNING), a pictorial and/or a safety message to alert you to hazards. DANGER indicates a hazard which, if not avoided, will result in death or serious injury.
safety warning • FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THESE INSTRUCTIONS. NEVER USE THE HEATER IN SPACES WHICH CONTAIN PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNERS, DUST PARTICLES, VOLATILE OR AIRBORNE COMBUSTIBLES, OR ANY UNKNOWN CHEMICALS. warning • NOT FOR HOME OR RECREATIONAL USE.
safety warning • Carbon Monoxide Hazard This heater produces carbon monoxide, which has no odor. Burning the heater in an enclosed space can kill you. Never use the heater in enclosed spaces such as a tent, a camper, any vehicle or recreational vehicle (RV), enclosed shelter, or any other enclosed areas. DANGER • Not for use in residential living areas or in non-adequately ventilated enclosed spaces. Never bring or store a propane cylinder indoors.
safety This heater is designed and approved for use as a construction heater in accordance with Standard ANSI Z83.7-2011/CSA 2.14-2011. CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE ANY QUESTIONS ABOUT APPLICATIONS. Other standards govern the use of fuel gases and heating products for specific uses. Your local authority can advise you about these. The primary purpose of construction heaters is to provide temporary heating of buildings under construction, alteration, or repair.
safety • An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance. • Heater must be placed on level and solid footing. • Never place anything, including clothes or other flammable items on heater. • Do not modify heater, or operate a heater that has been modified. • Adequate clearance for accessibility, combustion and ventilation (air supply) must be maintained at all times when heater is operating.
features warning • The hose assembly shall be pro tected from traffic, building material and contact with hot surfaces both during use and while in storage. warning • Not for use with ductwork. Minimum and Maximum inlet Pressure HL060F HL125F Min. 5 PSI Max. Bottle Pressure UNPACKING 1. Remove all packing items applied to heater for shipment. Keep plastic cover caps attached to inlet connector and hose/regulator assembly for storage. 2. Remove all items from carton. 3.
NEVER LEAVE HEATER UNATTENDE WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE features Features - Portable, stable and fully assembled. - 100% safety shut-off system. - Wind resistant and rain protected. - Adjustable input ratings (Except PT-40-GFA-A). - Continuous spark ignition or piezo spark ignition. - Adjustable Height Controller. Features components Figure 1: Product Features • Portable, stable and fully assembled. • Wind resistant and Propane rain protected.
propane supply/information Propane Supply/Information PROPANE You must provide the propane gas and cylinder(s). Use this heater only with a propane vapor withdrawal supply system. Refer to Chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum Gas , ANSI/NFPA 58. Your local library or fire department will have this booklet. LP Characteristics: • Flammable, explosive under pressure, heavier than air, and pools in low areas.
propane supply/information CAUTION • Propane is safe to use when properly handled. Careless handling of the LP cylinder could result in a fire and/or an explosion. • Always keep LP cylinder securely fastened and in an upright position. • Avoid tipping the LP cylinder on its side when connected to a regulator, since this may cause damage to the diaphragm in the regulator. • Handle valves with care. • Never connect an unregulated LP cylinder to a construction heater.
CAUTION dled. Careless handling of the LP cylinder could result in a fire and/or an explosion. Therefore: use. - All fittings must be protected when discon cylinder. - Always keep LP cylinder securely fastened and in an upright position. - Handle valves with care. - Never store an LP cylinder inside a buildi any gas burning appliance. disconnected tan CAUTION The stored in a building, g enclosed area. - Never connect an unregulated LP cylinder to a construction heater.
enclosed area. nstruction - Do not restrict inlet or outlet of heater. Heater is never to be used with ductwork. pre-lighting instructions -Lighting Instructions - Fasten full Propane tank and connect proper fitting to LP cylinder valve by turning COUNTERCLOCKWISE. FORE THE • Fasten full Propane tank and connect proper fitting to LP cylinder valve - With heater gas valve knob still in OFF position, turn ON LP by cylinder turningvalve COUNTERCLOCKWISE. and check for leaks with soap solution.
ventilation Ventilation caution • Always provide a fresh air opening in the heated space of at least three square feet (2,800 sq. cm.) for each 100,000 BTU/hr of heater output. • a two-car garage door open 6 inches, or • a single car garage open 9 inches, or • two thirty two inch wide windows open 15 inches.
lighting instructions Lighting Instructions TO START 1. Connect power cord to a properly grounded three (3) prong 120V, 60 Hz, extension cord. Extension Cord Wire Requirements: 6 to 10 feet (1.8 to 3 meters) long, use 18 AWG conductor. 11 to 100 feet (3.4 to 30.53 meters) long, use 16 AWG conductor. 101 to 200 feet (30.8 to 61 meters) long, use 14 AWG conductor. 2. Connect heater to a proper LP cylinder. 3. Turn gas valve clockwise to OFF position. 4. Wait five (5) minutes for any gas to clear.
storage/maintenance Storage/Maintenance Always disconnect the heater from the LP cylinder before putting the heater into storage. If for any reason the heater is to be stored indoors, the tank MUST be disconnected from the LP cylinder, and the cylinder stored outdoors in a well-ventilated area, out of the reach of children, and in accordance with the Standard for Storage and Handling of Liquefied Gases, ANSI/NFPA 58 - latest edition and Natural Gas and Propane Installation Code, CSA 149.1.
wiring diagrams NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED A FUEL SOURCE NEVER LEAVE TO HEATER UNATTENDED Wiring Diagrams PIEZO/MANUAL SPARK MODELS Wiring Diagrams WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE Wiring Diagrams NOTE: If any original wiring as supplied with the heater must be replaced, it must be with type AWG 105°C wire or its equivalent, except as indicated.
parts list EXPLODED VIEW 2 6 21 NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE 19 24 28 27 5 4 Propane Forced Air User’s Manual 3 25 20 18 Exploded View 8 11 17 16 15 10 14 13 © 2012, Pinnacle Products International, Inc.
parts lists parts breakdown REF # DESCRIPTION HL060F HL125F 1 Outer Shell 22-524-0021 22-524-0022 2 Inner Shell Assembly 22-524-0004 22-524-0005 3 Base 22-501-0001 22-501-0002 4 Height Controller 22-512-0005 22-512-0008 5 Base Cover 22-508-0001 22-508-0002 6 Inner Shell Cap 22-505-0010 22-505-0011 7 Multi Bracket Assembly 22-504-0002 22-504-0003 8 Thermal Switch 22-603-0010 22-603-0001 9 Tubing Assembly 22-605-0001 22-605-0002 10 Nozzle 22-081-0014 22-081-0015 11
troubleshooting Troubleshooting troubleshooting chart Problem Possible Case Solution Fan does not turn when electricity is connected 1. No electric power to heater. 2. Blades of fan in contact with heater housing. 3. Fan blades bent. 4. Fan motor defective. 1. Check current at outlet. If voltage is correct, inspect extension and power cords for cuts,frays or breaks. 2. Check housing for damage. Be sure there are no dents in the housing obstructing the fan. 3. Straighten all fan blades. 4.
warranty LIMITED WARRANTY BE Pressure Supply Inc. warrants this heater to the original retail purchaser only, to be free from defects in material and workmanship for a period of one (1) year from the date of initial purchase. This product must be properly installed, maintained and operated in accordance with the instructions provided. BE Pressure Supply Inc. requires reasonable proof of your date of purchase from an authorized retailer or distributor.
warranty BE Pressure Supply Inc. assumes no responsibility for any defects caused by third parties. This Limited Warranty gives the purchaser specific legal rights; a purchaser may have other rights depending upon where he or she lives. Some states do not allow the exclusion or limitation of special, incidental or consequential damages, or limitations on how long a warranty lasts, so the above exclusion and limitations may not apply to you. BE Pressure Supply Inc.
If you need assistance with the assembly or operation of this Heater please call 1-866-770-1711 26