AUTOMATIC DOOR CONTROL 24 V TRANSFORMER ACT ~ ~ BRIDGE RECTIFIER POWER 24 VAC RED POWER 24 VAC BLACK N/O COMMON GREEN - MC-25 GRAY WHITE 3 2 1 6 5 4 + RED COMMON RELAY 1 RELAY 2 - + DC-ELECTRIC STRIKE COM N/O 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL: www.beasensors.com NOTE: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #1. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT.
110 VAC orange brown jumpers on 2&3/ 5&6 dry grey grey RELAY #1 Com NC MC-25 #2 RELAY #1 RELAY #2 NO NC Com brown jumpers on 1&2/ 4&5 dry input from N.O. ISO Relay input from pushplate MC-25 #1 NO orange 24 VAC NO Com RELAY #2 NO NC 24V coil ISO24 RELAY ~ PUSH PLATE ~ ACT COM RECTIFIER + yellow blue red black blue yellow NC Com - SAf. DOOR CONROL WITH AUTOMATIC FLUSH BOLTS B.E.A., Inc.
gray red MC25 #1 WET CONTACTS gray black yellow blue orange brown ELECTRIC STRIKE PUSH PLATE COMMON 8 3 4 7 MC25 #2 DRY CONTACT data + 7 data - 6 NC 5 NO 4 COM 3 PWR 2 PWR 1 ACTIVE red ACTIVE black COMMON red/ white white green green brown orange DOOR CONTROL #2 LO-21S LOCK OUT RELAY gray yellow blue red + black - DK-12/ BODYGUARD brown 6 gray gray 5 orange DOOR CONTROL #1 ISO24 RELAY B.E.A., Inc.
DOOR POSITION SWITCH 24 V TRANSFORMER 115 VAC orange brown MC-25 N/O gray 3 2 1 RELAY 1 JP2 PUSH PLATE gray JP1 COMMON red (COM) purple (N/C) 6 5 4 RELAY 2 COMMON N/O blue yellow CARD READER BRIDGE RECTIFIER + - Common Activation DOOR CONTROL OPTIONAL NOTES: 1) JUMPERS JP1 & JP2 ARE PLACED ON PINS 2,3 AND 5,6 FOR WET CONTACTS. 2) DOOR POSITION SWITCH CONTACTS CLOSED WHEN DOOR IS CLOSED.
5 & ' ' & & ' ( ! 4)$% ) " ; 6 5- ()* # + $ + % ++ 1 % ) ,1 3 -3( *) ,4 ( % $ 1 # 3 " &$" 2 ( ! 1 3 1 . 3 / &$" 2 (%0 *) ,4 % 4 !"#$% %% %$ %" 14 = = =83 = " # $#% ) ( 3; ( 6 - ; 67 <6 8 8 6 :) 4 ;6 ; 85 5 9 65 > =)=9 ( <= 5 5 9 <6 = $ #& ' ( ) %* ) * B C'%$ ) 6 = -3? 8+ %!$ ! > + 6 56 %00 +@ 7"%$:$"/'"%00 A B 7"%$:$"/'"%0% = 6 6 6= < ( 1 () 1 -3 14 1, ) .
24 V TRANSFORMER 115 VAC EXTERNAL POWER SUPPLY orange brown MC-25 gray gray 3 2 1 RELAY 1 JP2 N/O JP1 COMMON PUSH PLATE red (COM) purple (N/C) 6 5 4 RELAY 2 COMMON N/O blue yellow CARD READER BRIDGE RECTIFIER + - Common Activation DOOR CONTROL OPTIONAL MAGLOCK B.E.A., Inc. NOTES: 1) JUMPERS JP1 & JP2 ARE PLACED ON PINS 1,2 AND 4,5 FOR DRY CONTACTS. 2) BRIDGE RECTIFIER SUPPLIED BY OTHERS.
SARGENT POWER SUPPLY 120VAC 24 V TRANSFORMER GND RELAY 24VAC COM RED COMMON N/O BLACK N/O * N.C. = CONTACT CLOSED WHEN RELAY NOT POWERED DOOR CONTROL ACT COM SARGENT PANIC DEVICE +24VDC -24VDC 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL: www.beasensors.com TITLE: MC-25 w/ SARGENT EL PANIC DEVICE & AUTOMATIC DOOR OPERATOR IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC.
VOLTAGE FOR RELAY FROM EXISTING APT. BUZZER OR FIRE ALARM SYSTEM 24 V TRANSFORMER ~ ~ BRIDGE RECTIFIER + COM RED COMMON N/O BLACK N/O - + - COM N/O DOOR CONTROL ACT D/C ELECTRIC STRIKE COM OPTIONAL NOTES: 1) JUMPERS JP1,JP2 ARE PLACED ON PINS 1,2 AND 4,5 FOR DRY CONTACTS ON RELAY OUTPUT #2. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER AND BRIDGE RECTIFIER VOLT/ AMPERE RATING IS DETERMINED BY CURRENT DRAW OF ELECTRIC STRIKE.
COMPUTER SYSTEM POWER SUPPLY 24 V TRANSFORMER POWER 24 VAC POWER 24 VAC RED BLACK GREEN N/O COMMON WHITE RED COMMON BLACK N/O DOOR CONTROL POWER 24 VAC POWER 24 VAC N/O ACT MAGLOCK COM RED BLACK GREEN COMMON WHITE 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL: www.beasensors.com NOTES: 1) JUMPERS JP1 & JP2 ARE PLACED ON PINS 1,2 AND 4,5 FOR DRY CONTACTS. 2) TYPE OF RELAY WILL BE DETERMINED BY MAGLOCK VOLTAGE (12 OR 24 VOLTS).
24 V TRANSFORMER ~ ~ BRIDGE RECTIFIER - COM RED COMMON N/O BLACK N/O + + COM N/O DOOR CONTROL ACT D/C ELECTRIC STRIKE COM OPTIONAL 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL: www.beasensors.com NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #2. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER VOLT/ AMPERE RATING IS DETERMINED BY CURRENT DRAW OF ELECTRIC STRIKE.
ACTIVATION gray DOOR #1 gray yellow gray MC25 #2 red DRY CONTACT orange brown black MOTOR #2 1.5sec DELAY 24 VAC ISO 24VAC COIL TRANSFORMER 120 VAC KM 2000 DOOR CONTROL white blue ELECTRIC STRIKE orange orange brown 0.5sec DELAY ~ + RECTIFIER ~ - yellow red WET CONTACT black MC25 #1 blue gray com n/o DOOR #2 MOTOR B.E.A., Inc.
24 V TRANSFORMER POWER 1 N/O2 COMMON 3 ~ * N.C. = CONTACT CLOSED WHEN RELAY NOT POWERED ~ BRIDGE RECTIFIER COMMON ACTIVATE + - RELAY - + RED PUSH TO OPEN COM GRAY BLACK N/O GRAY PURPLE D/C ELECTRIC STRIKE 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL: www.beasensors.com NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #2. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT.
24 V TRANSFORMER POWER 24 VAC RED BLACK POWER 24 VAC GREEN N/O WHITE COMMON ~ ~ BRIDGE RECTIFIER COMMON ACTIVATE - - + + RED PUSH TO OPEN COM GRAY BLACK N/O GRAY PURPLE NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #2. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER AND BRIDGE RECTIFIER VOLT/ AMPERE RATING IS DETERMIND BY CURRENT DRAW OF ELECTRIC STRIKE.
24 V TRANSFORMER POWER 24 VAC RED BLACK POWER 24 VAC GREEN N/O WHITE COMMON ~ ~ BRIDGE RECTIFIER COMMON ACTIVATE - + COMMON N/O OPTIONAL PURPLE PUSH TO OPEN COM GRAY BLACK N/O GRAY RED MAGLOCK NIGHT MODE KEY SWITCH NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #1. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER AND BRIDGE RECTIFIER VOLT/ AMPERE RATING IS DETERMIND BY CURRENT DRAW OF MAGNETIC LOCK.
24 V TRANSFORMER ~ RED BRIDGE RECTIFIER COMMON ACTIVATE - RED PUSH TO OPEN ~ COM GRAY BLACK N/O GRAY PURPLE BLACK PURPLE + + PANIC HARDWARE NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #1. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER AND BRIDGE RECTIFIER VOLT/ AMPERE RATING IS DETERMIND BY CURRENT DRAW OF ELECTRIC PANIC. 4) MAGNETIC REED SWITCH MUST BE CLOSED WHILE DOOR IS OPEN.
24 V TRANSFORMER ~ ~ BRIDGE RECTIFIER + - RED PUSH TO OPEN COM GRAY BLACK N/O GRAY PURPLE COMMON A/C ELECTRIC STRIKE N/O OPTIONAL COMMON ACTIVATE RED GRAY BLACK GRAY PURPLE COMMON ACTIVATE 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL: www.beasensors.com NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #1. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT.
LEFT APPRCH SIDE SSCAN RIGHT APPRCH SIDE SSCAN 24 V TRANSFORMER DOOR POSITION SWITCH CLOSED CONTACTS WHEN DOOR IS CLOSED BODYGUARD DATA + 7 blue DATA - 6 brown N.C. 5 N.O.