START UP
Before turning on the power make sure you have read the
Start Up instructions on page 6. When your hot tub power is
first turned on it will display a series of numbers identifying the
software version and the voltage input. It will then go into a 4
minute priming mode indicated by a Pr on the LCD display.
During priming mode the HushPump™ will circulate the water
through the filter and heating system to allow the temperature to
be read. If your tub is not HushPump™ equipped the jet pump
will not turn on until the prime mode times out or the
button is pressed to time out early. During prime mode the jet
pumps can be turned on to make sure they are fully primed and
moving water in the tub. Do not allow an unprimed jet pump
to run for more that 10 seconds. If the fill water temperature
is below 50°F/ 9.5C freeze protection will activate all pumps
immediately. While the circulation pump is running the display
will show a - - °F indicating current temperature is not known.
This will take two minutes. Once temperature is known it will be
displayed on the LCD.
TEMPERATURE ADJUSTMENT
The temperature range is 80°F - 104°F
26.0°C – 40.0°C. The default is 100°F/37.5°C. Any temp
changes are saved in the system memory if power is interrupted.
Use the button to increase and the button to lower
the set points. After showing set temp the LCD will revert back to
current water temp.
Note: if set temp is lowered more than 3°F/1.5C below current
water temp the HushPump™ will stop. The circulation will
restart every 30 minutes to check if water temp has come down
to set temp. It will also run continually during programmed times.
HEATING MODES
Std –
Standard Mode
: (Default mode) In Standard Mode the
water is always heated to the set temperature. The display will
show the current temperature and the word STANDARD.
Ecn –
Economy Mode
: In Economy Mode the water is heated
only during the filter cycle times. Default times are 8:00 am to
10:00 am for cycle 1 and 8:00 pm to 10:00 pm for cycle 2. If
using economy you may need to alter these times to make sure
the water is at your desired temp during your usual tub use
times. The display will alternate between Ecn and the current
temperature and display the word ECONOMY.
SLP –
Sleep Mode
: In Sleep Mode the water is only heated to
within 20°F/11°C of your set point and the heater only comes on
during the programmed filter cycle times. This mode is typically
only used for vacation time. The display will alternate between
the current temperature and SLP.
To change heating modes press the button then the
button.
MASSAGE1
To activate this jet pump press the 1 button once to
activate low speed, The icon will flash off and on, on the
LCD display. Press again to activate high speed and the icon
will become solid on the display. Press a third time to turn the
pump off. The low speed will turn off automatically after 4 hours
and the high speed will turn off after 15 minutes.
Note: If tub is HushPump™ equipped the low speed of Massage
1 will come on automatically for 1 minute at the start of each
filter cycle to purge the plumbing lines. If the purge time is not at
the time of day you want change the filter times.
MASSAGE 2
To activate this jet pump press the 2 button once to
activate low speed, The icon will flash off and on, on the
LCD display. Press again to activate high speed and the
icon will become solid on the display. Press a third time to turn
the pump off. The low speed and the high speed will turn off
automatically after 15 minutes.
ET-70 TOPSIDE CONTROL PANEL OPERATING INSTRUCTIONS
LightWarm
Cool Massage1 2
Time
Mode/Prog
LightWarm
Cool Massage1 2
Time
Mode/Prog
LightWarm
Cool Massage1 2
Time
Mode/Prog
13