Operating instructions

Note: If tub is HushPump™ equipped the low speed of Massage
2 will come on automatically for 1 minute at the start of each
filter cycle to purge the plumbing lines. If the purge time is not at
the time of day you want change the filter times.
LIGHT
To activate, press the button once to turn on and again to
turn off. The light will automatically turn off after 4 hours. If your
tub has an Everlite™6 or any additional lighting features see the
instructions in this manual.
TURBO (OPTIONAL)
To activate, press the button once to turn on and again to
turn off. The Turbo will turn off automatically after 15 minutes.
The Turbo will come on automatically for 30 seconds at the start
of each filter cycle to purge the Turbo plumbing. If the purge time
is not at the time of day you want change the filter times.
SETTING TIME CLOCK AND FILTER CYCLES
Time Set
To set the time clock to your local current time press the
button, then the button and Set Time appears. Press the
button to advance the time or the to back up the
time. The time will advance quickly 5 seconds after pressing the
or buttons. Use the same button to stop the clock at
the desired time.
Filter Cycle Setting
Changing filter cycles is not necessary as it comes preset from
the factory as outlined in Economy heat mode, but if you want to
change them follow instructions below.
Once time of day is set press the button to set start time
of Filter cycle 1. If your tub is Hush equipped changing filter
cycles does not affect the time the Hush runs. It tells the system
when to turn on the heater if you are using the Economy heat
setting. If your tub is non Hush changing the cycle time tells the
two - speed pump 1 when to operate for a filter cycle. Avoid
programming a long filter cycle that runs during the day time
hours in hot summer weather as it could cause the water to
overheat. Use the or buttons to advance or backup
the Filter 1 start time. Press the same button to stop the time
once you reach the desired start time. Press the button to
advance to the Filter 1 stop time and use the same procedure as
above to adjust. Press the again to select Filter 2 start time
then use the same procedure as above to adjust, then press
to select Filter 2 stop time and once set, press to exit the
menu.
Make sure you do not program the cycles to overlap the start or
stop time of either cycle.
Any changes to filter cycles and time are stored in the system
memory and will be retained in the event of a power outage.
PANEL LOCK
This feature might be used if you do not want to anyone to
operate the tub in your absence. To lock the panel press, ,
then , then within three seconds. A pad lock icon will
appear on the LCD. To unlock press then , then
within three seconds.
TEMPERATURE LOCK
This feature might be used to prevent other tub users such as
children from adjusting the tub set temperature. To lock the set
temperature press, then then then within
3 seconds. To unlock press then then within 3
seconds.
DIAGNOSTIC DISPLAY MESSAGES
Power to Hot Tub is off
--°F Current temperature not known
OHH Possible overheated heater do not enter Hot Tub
OHS Possible overheated Spa do not enter Tub
SnA Sensor problem
Snb Sensor problem
SnS Sensors out of balance
HFL Possible flow through heater problem
LF Confirmed flow through heater problem
dr Possible dry heater problem
drY Confirmed dry heater problem
ICE Freeze condition sensed
Refer to diagnostic and trouble shooting section on page 25 for
more detailed information.
SHOCK HAZARD!
NO USER SERVICEABLE PARTS.
DO NOT ATTEMPT SERVICE OF THIS CONTROL. CONTACT
YOUR DEALERSHIP OR SERVICE PROVIDER FOR
ASSISTANCE. FOLLOW ALL OWNER’S GUIDE POWER
CONNECTION INSTRUCTIONS. INSTALLATION MUST
BE PERFORMED BY A LICENSED ELECTRICIAN AND
ALL GROUNDING CONNECTIONS MUST BE PROPERLY
INSTALLED.
WARNING
TAMPERING WITH OR MODIFYING
THIS EQUIPMENT MAY VOID YOUR
GUARANTEE.
WARNING
ALWAYS TEST WATER TEMPERATURE
PRIOR TO ENTRY USING THE TOPSIDE
CONTROL PAD. ENSURE COMFORT BY ALSO CHECKING
WATER WITH A THERMOMETER.
WARNING
14