Operating instructions

STARTUP
Before turning on the power make sure you have read the Start Up
instructions on page 6. When your hot tub power is first turned on
it will display a series of numbers identifying the software version
and the voltage input. It will then go into a 4 minute priming mode
indicated by a Pr on the LCD display. During priming mode
the HushPump™ will circulate the water through the filter and
heating system to allow the temperature to be read. If your tub
is not HushPump™ equipped the jet pump will not turn on until
the prime mode times out or the button is pressed to time
out early. During prime mode the jet pump can be turned on to
make sure they are fully primed and moving water in the tub. Do
not allow an unprimed jet pump to run for more that 10 seconds.
If the fill water temperature is below 50°F/ 9.5C freeze protection
will activate all pumps immediately. While the circulation pump is
running the display will show a - - indicating current temperature
is not known. This will take two minutes. Once temperature is
known it will be displayed on the LCD.
TEMPERATURE ADJUSTMENT
The temperature range is 80°F - 104°F / 26.0°C – 40.0°C. The
default is 100°F/37.5°C. Any temp changes are saved in the
system memory if power is interrupted. Press the button
to increase or lower the set points. If the is pressed the set
point will flash. Each press will move the set point 1 degree. If the
set point is moving the wrong direction then stop pressing, let the
temperature display stop flashing then press again to move the set
point in the other direction. After adjusting the set temp the LCD
will revert back to current water temp.
Note: if set temp is lowered more than 3°F/1.5C below current
water temp the HushPump™™ will stop. The circulation will
restart every 30 minutes to check if water temp has come down to
set temp. It will also run continually during programmed times.
HEATING MODES
St
Standard Mode (Default Mode
) In Standard Mode
the water is always heated to the set temperature. The display
will show the temperature always with HushPump™ equipped
systems. If non HushPump™, current water temperature will
be shown when the pump is running and – when pump is not
running. If your tub is not equipped with a HushPump™ the 2
speed pump will come on every 30 minutes outside of filter cycles
to poll for current water temperature. If you do not want this to
happen use the Economy mode below.
Ec
Economy Mode:
In Economy Mode the water is heated
only during the filter cycle times. The factory default is F4 ( 4
hours),2C (twice a day) If using the Economy mode you may need
to alter these times to make sure the water is at your desired
temp during your usual tub use times. The first filter cycle starts
6 minutes after power is turned on. The display will alternate
between the current temperature and Ec.
SL
Sleep Mode:
In Sleep Mode the water is only heated to
within 20°F/11°C of your set point and the heater only comes on
during the programmed filter cycle times. This mode is typically
only used for vacation time. The display will alternate between the
current temperature and SL
To change heating modes press the button then the
button.
MASSAGE
To activate this jet pump press the button once to activate
low speed, twice to activate high speed and three times to turn
the pump off. The low speed will turn of automatically after 4
hours and the high speed will turn off after 15 minutes. If tub is
HushPump™ equipped, the low speed of the jet pump will come
on automatically for 1 minute at the start of each filter cycle to
purge the plumbing lines.
LightLightLight TempTempTemp
MassageMassageMassage
HeatHeatHeat
ET-50 TOPSIDE CONTROL PANEL OPERATING INSTRUCTIONS
15