PROBLEM SYMPTOM MOST LIKELY CAUSE SOLUTION
G.F.C.I. breaker will not stay on or
trips intermittently.
If hot tub is new; the load neutral wire has
been inserted on the neutral buss in the
panel. Load neutral wire should be inserted
into the G.F.C.I. load neutral connection.
Call your Electrician to change location of the
load neutral wire.
Heater element is defective and leaking
current to ground.
Call your dealer for service to replace the
heater element.
G.F.C.I. is worn out or defective. Class A,
G.F.C.I. breakers should not trip below 5
milliamps of current leakage.
Call your electrician to replace your G.F.C.I.
Jet pump is surging on high speed. Water level is too low on hot tubs that use
a jet pump for filtering.
Raise water level in hot tub to at least ½ way
up the skimmer opening.
Plug in center of Microfilter basket is not
in place on non HushPump™ equipped
hot tub.
Install plug in basket, insert from top of
basket.
RFM jet nozzles are pointed toward small
suction fitting in foot well.
Redirect nozzles away from the small suction
fitting. Turn off all air control for RFM jets.
Neck jet does not shut off. Internal portion of two piece neck jet has
been unscrewed by turning too far to the
left.
Carefully pry the faceplate off with a flat head
screw driver and then thread internal back
in. Then pop face plate back on and tighten
internal by turning face plate clockwise.
ACSS Remote control is not
operating the jets and light
functions from in the hot tub but
will operate from out of the hot tub.
CD player console door is open. Close CD player console door.
Emitter on door window has come off. Re-glue emitter to door glass with super glue.
Line up between receiver eye on CD player
face and hot tub function receiver eye below.
See CD player Guide for receiver eye location.
ACSS remote control is not
operating CD player functions from
in the hot tub but will operate from
out of the hot tub.
CD player console door is open. Close CD player console door.
Emitter on door window has come off. Re-glue emitter to door glass with super glue.
Line up between receiver eye on CD player
face and hot tub function receiver eye below.
See CD player Guide for receiver eye location.
Remote control does not work hot
tub or CD Player functions pointing
at CD player.
Batteries need replacing. Remote control
is defective.
Replace batteries or see your Beachcomber
dealership.