Beachcomber Hot Tubs Owner’s Manual
Table of Contents Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 • Beachcomber Safety Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 • Starting up a Beachcomber Hot Tub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 • Water Care Product Startup Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Equipment Configuration Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of drowning from hair and body entrapment, install suction fitting(s) with a marked flow rate that is not less than the flow rate marked on the remote packaged unit.(note: these are factory installed). Do not operate the tub with any of the suction fitting covers off. These covers are there to prevent hair or objects from being sucked into the plumbing. See Figure 1. IMPORTANT! READ AND FOLLOW ALL INSTRUCTIONS.
Warning: Any person with the following conditions should consult their Physician before using a hot tub. Diabetes, High blood pressure, Heart disease, Circulatory problems, Pregnant women or those taking medication prescribed by their Physician. Do not allow electrical devices to such as portable stereos, TVs, hair dryers within 5 feet/1.5 meters of the tub. Failure to do so could result in death due to electrocution should the device fall in the water.
3. Fill the hot tub to half way up the skimmer opening. Note: If your hot tub is Hush Pump equipped your level can be lowered to one third up the skimmer opening. This will allow for more displacement if the hot tub is subjected to use by more than the recommended amount of people for that model. See Figure 5. how many times a day the filter hours occur.
EQUIPMENT CONFIGURATION DIAGRAMS -4-
EQUIPMENT CONFIGURATION DIAGRAMS -5-
EQUIPMENT CONFIGURATION DIAGRAMS -6-
EQUIPMENT CONFIGURATION DIAGRAMS -7-
EQUIPMENT CONFIGURATION DIAGRAMS -8-
DIGITAL SYSTEMS, PROGRAMMING, OPERATION AND ERROR MESSAGES 300 Series Digital 1000 System including Model 160 PRESET FILTER CYCLES Your hot tub is set to filter itself twice a day. The first filter cycle will start one minute after the hot tub is powered up. The second filter cycle will begin twelve hours after the start of the first filter cycle. Filter cycle duration is 2 or 6 hours long, and is set at the time of delivery.
"FL" "Flow" (Flashing) – Flow of water is inhibited. Check and open any closed knife valves. Check for correct water level. Clean or replace your Microfilter. "FL" "Flow" (Not flashing) - Flow switch has malfunctioned. Contact your dealer or service organization. "Sn" "Sensor" - Hot tub is shut down. The high-limit or water temperature sensor is not working. Contact your dealer or service organization. "Sb" "Standby" - Hot tub is in standby mode. All hot tub functions are disabled except for freeze control.
DIGITAL SYSTEMS, PROGRAMMING, OPERATION AND ERROR MESSAGES 500 Series Digital 2000 System START UP When your hot tub is first powered up, it will automatically heat and maintain 100°F / 37.5°C until you change the set temperature. TURBO (OPTIONAL) Press the pad to turn the blower on and off. If left running, the turbo automatically turns off after 15 minutes. TEMPERATURE ADJUSTMENT (60°F-104°F) / (16°C-40°C) Press the pad to display the temperature previously set.
During filtration the optional ozone generator (if installed) will run. If Turbo equipped, the turbo will come on for 30 seconds at the start of the first filter cycle. "Sb" Standby" - Hot tub is in standby mode. All hot tub functions are disabled except for freeze control. Press any panel button to resume operation. STANDBY MODE Press then within 3 seconds to prevent the hot tub from operating at any time. "Sb" will appear on the display Standby mode should be used when replacing the filter.
DIGITAL SYSTEMS, PROGRAMMING, OPERATION AND ERROR MESSAGES 700 Series Digital 3000 System to disable the heater. Press , to see "SET STOP FILTER 1" and adjust the time with or as done above. Press to see "SET START FILTER 2" and proceed as above. Pressing will enter the new filter cycle times into the system and display the current water temperature. At the start of each cycle, the turbo (if installed) will turn on for 30 seconds to clean out the air channel.
For hot tubs with turbo option: Press , , , then the pad within 3 seconds to lock. To unlock, press the , , pads within 2 seconds. MASSAGE 2 Press the 2 pad once to activate the pump2’s low speed, again for the pump’s high speed, and once more to turn off the pump. The pump’s low speed turns off after 1 hour. The pump’s high speed turns off after 15 minutes of use. STANDBY MODE Press or then within 3 seconds, to prevent the hot tub from operating at any time.
"Sn1" "Sensor1" - Hot tub is shut down. The high-limit sensor is not working. Contact your dealer or service organization. "Sn3" "Sensor3" - Hot tub is shut down. The water temperature sensor is not working. Contact your dealer or service organization. "Stby" "Standby" - Hot tub is in standby mode. All hot tub functions are disabled except for freeze control. Press any panel button to resume operation. Heat Light Flashing "Summer Standby Mode" – Filtering has stopped: water temperature is 3°F / 1.
MODEL 320M AND 320 XM MECHANICAL SYSTEMS These are non digital systems which use a mechanical equipment pak. If you have the 110 volt version the heater will not work when you have the pump on high speed due to the amperage capacity of the 110 volt circuit in your house. With the 240 volt version, the heater will operate when the pump is turned to high speed. High–Limit Reset This is a safety device that will shut the system down if a water temperature above 110ºF is sensed at the heater housing.
refilling. Use test strips to check or have your dealer perform the test. The ideal range is 100-120 ppm. WATER CARE AND MAINTENANCE Now that you are familiar with the operation of your Beachcomber hot tub you need to become familiar with the care and maintenance of it. 4. Calcium Hardness. Too high a level can cause cloudy water or scaling on the hot tub surface and heating element. Too low a level can lead to excess foaming in the water.
Heatshield and Step Tops HOT TUB CARE AND MAINTENANCE As with any vinyl product that is exposed to the weather, the better the care, the longer it will last. Use a mild dish soap solution to remove dirt on the cover and then treat the vinyl with Cover All. Avoid application in the hot sun. Note: While the Heatshield is strong enough to withstand up to 2 feet of snow it is not designed to support the weight of children or pets walking on it or adults sitting on it.
or the seat jets on the left of the hot tub if the water flow is diverted to them. On all models more air is drawn in when the jet pump is on high speed than when the pump is on low speed. Air Control Valves OPERATION OF HOT TUB INTERIOR FEATURES Massage Inserts, or “Jets” The jets in a Beachcomber hot tub are known as Energ-Jets™1-small, 2-medium and 3-large. They are interchangeable within the same sizes. Simply turn them counterclockwise until they click and pop out.
To replace a burned out bulb, turn off the power, drain the hot tub, and unscrew the lens with the wrench provided with your hot tub. Carefully pull out the burned out bulb and then replace with a new one. Screw the lens back in until tight. Do not over tighten! If the hot tub has the optional Everlite™ then, when turned on it will cycle between the three colors, turn off and on within 5 seconds and it will stop at one of the colors. Continue turning off then on two pick one of the other two colors.
4. Lock your cover on the hot tub to maintain a safe environment for pets or children. If in a high wind area install Hurricane straps available from your local Beachcomber dealer. Upon returning do the following: 1. Check pH and sanitizer level and adjust if necessary. DRAINING A BEACHCOMBER HOT TUB Before draining, check the sanitizer level; it should not be above 1.0 to ensure no harm is done to the surrounding environment. Turn the power off at the breaker.
one pump to the front of the other pumps. There is also a 1 minute, low speed purge cycle that happens at the start of each filter cycle. Note: If refilling your hot tub during winter, most source water is colder than 50ºF / 10ºC. This means your freeze protection will activate as soon as the system is turned on. On 700 Series hot tubs, we recommend that you do not use the economy setting during freezing weather.
HOT TUB OPERATION TROUBLESHOOTING GUIDE Problem Symptom Control panel display is alternating between FL or FLO and the water temperature. The pump is running. Most Likely Cause Filter is dirty Knife valve is closed. On non Hush tubs, jets that receive flow from circulation pump are closed Low water level or water refill causing an airlock in the system. Control panel display is alternating between FL or FLO and the pump is not running.
Pump is surging on high speed. Hush pump is not running 24 hours a day. G.F.C.I. breaker will not stay on or trips intermittently. Neck jet on 500 or 700 series tubs does not shut off. Water temperature is always above the set temperature. Remote control for CD player does not work from inside the tub. RFM jet nozzles are pointed toward large suction fitting in foot well. Filter cycles have been altered at the control panel. Children may have been messing around with buttons and changed the settings.
Remote control does not work when pointing directly at CD player. The water is cloudy. pH level is hard to keep balanced. Water is foaming a lot. Strong Chlorine or Bromine smell in tub. Acrylic surface has a white haze on it after tub is drained. Remote control batteries are low, or remote is defective. Sanitizer level is to low. Change batteries or contact your local dealer. Shock-treat the water and then maintain a sanitizer level of 3 – 5 ppm at all times.
BEACHCOMBER HOT TUB CARE AND MAINTENANCE RECORD Date Hose off filter element Soak filter element in cleaning solution - 26 - Drain and refill tub Clean and treat tub cover Re stain cedar cabinet
DETAILS CHART Hot Tub Model # 160 320 320M 320X 320XM 350 520 530 550C 550X 578 580 720 720RI 720X 730 740 750 System # 240 volt 5.5 kw Digital 1000 120 volt 1.5 kw Digital 1000 120 volt 1.5 kw Mechanical pak 240 volt 5.5 kw Digital 1000 240 volt 4 kw Mechanical Pak 240 volt 5.5 kw Digital 1000 240 volt 5.5 kw Digital 2000 240 volt 5.5 kw Digital 2000 240 volt 5.5 kw Digital 2000 240 volt 5.5 kw Digital 2000 240 volt 5.5 kw Digital 2000 240 volt 5.5 kw Digital 2000 240 volt 5.5 kw Digital 3000 240 volt 5.
Contact us: Beachcomber Home Office 13245 Comber Way, Surrey, B.C. Canada V3W 5V8 North American Customer Care 1.800.663.6557 San Diego Beachcomber Worldwide Centre 1.866.250.7878 Fax line: 760.560.7882 Arnhem Beachcomber European Centre 31 (0) 26 327 4822 Fax line: 31 (0) 26 323 7836 Toronto Beachcomber Development Centre: 1.800.268.3966 Fax line: 905.829.2848 Laval Beachcomber Development Centre: 1.866.389.7878 Fax: 450.781.8722 www.beachcomberhottubs.