Owner`s manual
START UP
When your hot tub is first powered up, it will
automatically heat and maintain 100°F / 37.5°C
until you change the set temperature.
TEMPERATURE ADJUSTMENT
(60°F-104°F) / (16°C-40°C)
Press the pad to display the temperature
previously set.This set temperature is flashed on the
display. In a few seconds, the numbers will stop
flashing, and the display will show the actual
temperature. Pressing the pad a second time will
cause the set temperature to increase or decrease
depending on what direction was last chosen. Each
press to follow will change the set temperature in
the same direction. If the opposite direction is
desired release the pad and let the display revert to
the actual water temperature. Press the pad to
display the set temperature, and again to make the
temperature change in the desired direction.Actual
water temperature will reappear on the display after
changing the temperature setting.
LIGHT/MASSAGE
Press the pad to cycle through the light and jets
features.The operating sequence is as follows: 1)
low-speed pump, 2) low-speed pump and light, 3)
high-speed pump and light, 4) high-speed pump
only, and 5) off.The low-speed pump automatically
turns off after 1 hour.The high-speed pump stops
after 15 minutes.The light turns off after 2 hours
of use.
PRESET FILTER CYCLES
Your hot tub is set to filter itself twice a day.The first
filter cycle will start one minute after the hot tub is
powered up.The second filter cycle will begin twelve
hours after the start of the first filter cycle. Filter
cycle duration is 2 or 6 hours long, and is set at the
time of delivery. During filtration, the low-speed
pump and ozone generator (if installed) will run.
Contact your local dealer to change the cycle.
STANDBY MODE
Press then within 3 seconds to prevent the
hot tub from operating at any time. "Sb" will appear
on the display. Standby mode should be used when
removing or replacing the filter.All hot tub functions
will be disabled except for freeze control. Press any
button to resume hot tub operation. Do not use
stand-by for draining and refilling; shut off the
power at your breaker panel.
DISPLAY MESSAGES
"OH"
"Overheat" - The hot tub has shut down. Either the
water has reached 112°F / 44°C, or the high limit
sensor has detected 118°F / 48°C at the heater.
DO NOT ENTER THE WATER. Remove the hot tub
cover and allow water to cool.At 110°F / 43°C, the
hot tub should automatically reset. If the hot tub
does not reset, then turn off all power to the hot tub
and contact your dealer or service organization.
- 9 -
DIGITAL SYSTEMS, PROGRAMMING, OPERATION AND ERROR MESSAGES