Pump is surging on high speed. RFM jet nozzles are pointed toward Redirect nozzles away from large
large suction fitting in foot well. suction fitting.
Hush pump is not running 24 Filter cycles have been altered at On 500 series turn power off then
hours a day. the control panel. Children may on again to reset.
have been messing around with On 700 series reset to default
buttons and changed the settings. times, Filter 1- 2am to 2pm, Filter
2- 2pm to 2am, using the touch
pad.Then advance time clock 24
hour ahead to reset.
If 700 series, power to the tub Wait until the start of the next filter
has been interrupted. cycle or advance time clock 24 hrs.
Water temperature is 3ºF/1.5ºC or When lowering the set point do not
more above set point and the heat go more than 2ºF, then wait for the
indicator is flashing. water to come down to that.
G.F.C.I. breaker will not stay If tub is new; the load neutral wire Call your electrician to change
on or trips intermittently. has been inserted on the neutral location of the load neutral wire.
buss in the panel. Load neutral wire
should be inserted into the GFCI.
Heating element is defective and Call your dealer for service to
leaking current to ground. replace the heating element.
G.F.C.I. is worn out or defective. Class Call your electrician to replace
A, G.F.C.I breakers should not trip your G.F.C.I.
below 5 Milliamps of current leakage.
Neck jet on 500 or 700 series Internal portion of two piece neck Carefully pry the faceplate off with
tubs does not shut off. jet has been unscrewed by turning a flat head screw driver and the
too far to the left. thread internal back in.Then pop
face plate back on and tighten
internal by turning face plate
clockwise.
Water temperature is always The temperature sensor is not fully Loosen nut on senior entry fitting
above the set temperature. inserted into the sensor well in and slide round grey wire forward
the tub. May have been pulled out until metal on plastic tapping
partly by mistake. Usually on Protec sound is heard.The tighten nut to
version tubs. hold wire.
During hot weather the filter cycles Reduce length of filter cycles.
are set too long and the 2 speed
circulation pump is creating heat.
Remote control for CD player Door for CD player console is open Close CD player console door.
does not work from inside the tub. Emitter on door glass has come off. Re glue emitter to door glass with
crazy glue. Line up with receiver
eye on CD player face. See CD play-
er manual for receiver eye location.
Remote control batteries may be Install new batteries.
dead.
- 24 -