Specifications

Programmable Control Instructions/Digital 3000 5 - 3
Start Up
When your hot tub is powered up, it begins running
in economy mode, which means that the heater will
only operate during the preset filter cycles. This
setting is designed for periods of little or no hot tub
use, but continues to filter twice a day and maintain
water quality. Pressing the pad switches the
spa to standard mode which automatically heats to
100
o
F/37.5
o
C or your desired temperature.
Time
You will see the words “SET TIME” flashing on the
display. To set the time, press , then .
Pressing or once will begin changing
the time in one-minute increments. Press either pad
to stop the time from changing. Press to
enter the correct time into the system.
Optional Filter Cycle Programming
While you are not required to set filter cycles, if you
want to change them, press within
3 seconds. “SET START FILTER 1” will appear on the
display. Press or to reset to filter
start time. When “SET HEAT” is on the display, press
on to warm the water during filtering, or
press “off” to disable the heater. Press ,
to see “SET STOP FILTER 1” and adjust the time
with or as done above. Press
to see “SET START FILTER 2” and proceed as above.
Pressing will enter the new filter cycle times
into the system and display the current water
temperature. At the start of each cycle, the turbo (if
installed) will turn on for 30 seconds to clean out
the air channel. The heater and the ozone generator
(if installed) will run for the duration of the filter
cycle.
Water Temperature (80
˚F-104˚F)/(26˚C-40˚C)
Press either or once to display the
last temperature that was set. If either pad is
pressed within 3 seconds, the temperature setting
will increase or decrease in 1
˚F
increments. Actual
water temperature will reappear on the display after
changing the temperature setting.
Time and Temperature Inversion
Press or , then 1 within 3
seconds to invert the time and temperature display.
Press the same sequence to set back.
Massage 1
Press the 1 pad once to activate the low speed
of pump 1. Press the pad’s low speed turns off after
4 hours. The pump’s high speed turns off after 15
minutes.
Massage 2
Press the 2 pad to turn pump 2 on and off. If
left on, the pump will turn off after 15 minutes.
Turbo (Optional)
Press the pad to cycle through the highest to
lowest setting, then to turn off the turbo. If left
running, the turbo automatically turns off after 15
minutes.
DIGITAL 3000 MANAGEMENT SYSTEM
TWO SPEED PUMP VERSION