Specifications
Questions and Answers about your Beachcomber Hot Tub 7 - 6
Fault indicated by control panel display
Refer to Section 5 for “Display messages”
for Digital controls.
The pump does not start during startup
• There may not be enough water in the
hot tub.
• Air may be in the lines, and needs to
be bled from the system.
Jets will not operate
• Check that the pump is properly
started up (primed).
• Jet nozzles could be plugged or
missing. Remove massage inserts
and clean. Ensure that all massage
inserts are there and in place.
Remove them and reinstall properly,
hand tightening only.
• Check for blockages at the suction
fitting(s) in the footwell.
• Check for blockages in the Microfilter
by removing the filter(s) and
inspecting. Note: Digital Management
System must be on standby.
• The water level may be too low.
• Ensure that the knife valves are fully
open.
Hot tub does not heat to temperature
• The thermostat may be set too low.
See Section 5 “Digital Operation
Instructions”.
• Filters may need to be cleaned or
replaced. Remove them and inspect.
• Water level may be too low.
• See Section 3 for bleeding air out of
the system.
• Pressure switch may not sense
enough pressure.
• The heater element or thermostat may
be defective.
Hot tub heats, but not to temperature
• Ensure that the hot tub is covered
properly by the heatshield.
• Extremely high wind or low
temperatures may affect heating
ability.
• Try closing the air controls to
conserve heat.
• Ensure that the step or doors are
properly closed to protect equipment.
• Heater element may be coated with
calcium, impairing its ability to heat
because of improper water balance.