Specifications

Questions and Answers about your Beachcomber Hot Tub 7 - 6
Fault indicated by control panel display
Refer to Section 5 for “Display messages”
for Digital controls.
The pump does not start during startup
There may not be enough water in the
hot tub.
Air may be in the lines, and needs to
be bled from the system.
Jets will not operate
Check that the pump is properly
started up (primed).
Jet nozzles could be plugged or
missing. Remove massage inserts
and clean. Ensure that all massage
inserts are there and in place.
Remove them and reinstall properly,
hand tightening only.
Check for blockages at the suction
fitting(s) in the footwell.
Check for blockages in the Microfilter
by removing the filter(s) and
inspecting. Note: Digital Management
System must be on standby.
The water level may be too low.
Ensure that the knife valves are fully
open.
Hot tub does not heat to temperature
The thermostat may be set too low.
See Section 5 “Digital Operation
Instructions”.
Filters may need to be cleaned or
replaced. Remove them and inspect.
Water level may be too low.
See Section 3 for bleeding air out of
the system.
Pressure switch may not sense
enough pressure.
The heater element or thermostat may
be defective.
Hot tub heats, but not to temperature
Ensure that the hot tub is covered
properly by the heatshield.
Extremely high wind or low
temperatures may affect heating
ability.
Try closing the air controls to
conserve heat.
Ensure that the step or doors are
properly closed to protect equipment.
Heater element may be coated with
calcium, impairing its ability to heat
because of improper water balance.