Operating instructions

LIGHT
To activate this press the button once to turn on and again
to turn off. The light will automatically turn off after 4 hours. If your
tub has an EverLite™ 6 or any additional lighting features see the
instructions on page 20 of this manual.
TURBO (OPTIONAL)
To activate this press the button once to turn on and twice to
turn off. The Turbo will turn off automatically after 15 minutes. The
Turbo will come on automatically for 30 seconds at the start of each
filter cycle to purge the Turbo plumbing.
SETTING FILTER CYCLES
Changing filter cycles is not necessary as it comes preset from the
factory as outlined in Economy heat mode instructions, but if your
tub is not equipped with Hush Pump™ and you want to change
them, use the following instructions. Press the then press
to bring up F2 keep pressing to select F4, F6, F8, FC
(12 hours). Then press to bring up 2C (two cycles per day). If
you want to change press to select 1d (day cycle) and again
to select 1n (night cycle). Press to exit programming.
DIAGNOSTIC DISPLAY MESSAGES
Power to Hot Tub is off
-- Current temperature not known
HH Possible overheated heater: do not enter Hot Tub
HS Possible overheated Hot Tub: do not enter Hot
Tub
SA Sensor problem
Sb Sensor problem
Sn Sensors out of balance
HL Possible flow through heater problem
LF Confirmed flow through heater problem
dr Possible dry heater problem
dY Confirmed dry heater problem
IC Freeze condition sensed
Refer to diagnostic and trouble shooting section starting on page
25 for more detailed information.
SHOCK HAZARD!
NO USER SERVICEABLE PARTS.
DO NOT ATTEMPT SERVICE OF THIS CONTROL. CONTACT
YOUR RETAIL STORE OR SERVICE PROVIDER FOR
ASSISTANCE. FOLLOW ALL OWNERS GUIDE POWER
CONNECTION INSTRUCTIONS. INSTALLATION MUST
BE PERFORMED BY A LICENSED ELECTRICIAN AND
ALL GROUNDING CONNECTIONS MUST BE PROPERLY
INSTALLED.
WARNING
TAMPERING WITH OR MODIFYING
THIS EQUIPMENT MAY VOID YOUR
GUARANTEE.
WARNING
ALWAYS TEST WATER TEMPERATURE
PRIOR TO ENTRY USING THE TOPSIDE
CONTROL PAD. ENSURE COMFORT BY ALSO CHECKING
WATER WITH A THERMOMETER.
WARNING
16