Operating instructions

Removing these allows the last bit of water in the bottom
half of the pump to drain out.
4. Remove the Microfilter cartridge and store in a dry
place.
5. Lock Heatshield and attach Hurricane strapping if in
high wind areas.
6. Provide Extra Support for the Heatshield in heavy snow
by placing a 4x8 sheet of 3/4” plywood on top of the
Heatshield.
Do’s and Don’ts
DO’S
1. Read this Owner’s Guide thoroughly and follow the safety
guidelines provided.
2. If you have questions not covered in this guide, call
your local Beachcomber store. Or, call 1.800.663.6557
from 8:00 am - 4:30 pm PST.
3. Follow water care instructions and guidelines. Failure to
do so can result in damage or problems to the hot tub or
the equipment.
4. Always leave your Heatshield open half way when
shocking your water.
5. Always supervise children in and around a hot tub. Do
not allow children to use the hot tub unsupervised.
6. Test your GFCI circuit protector at least once a month
to ensure it is working correctly.
7. Rinse your Microfilter at least once a week if the hot
tub is used daily.
8. Always check the water temperature before entry.
DON’TS
1. Don’t enter your hot tub if the sanitizer level is
not adequate. This can cause respiratory and skin
problems or disease.
2. Don’t walk on, sit on or put heavy weight on the
Heatshield cover. This can cause the foam inserts to
break.
3. Don’t leave the hot tub exposed to the sun if empty.
Always cover the hot tub with your Heatshield.
4. Don’t allow use of the hot tub by children without adult
supervision.
5. Don’t attempt to repair or service equipment. Consult
your Beachcomber store.
6. Don’t attempt to drain and refill your hot tub during
freezing temperatures.
7.
Don’t use glassware in or around your hot tub.
8.
Don’t enter a hot tub if the temperature is higher than
104
0
F/40
0
C.
9. Don’t operate the hot tub with an inadequate water
level.
Diagnostic Display Messages & Trouble Shooting Guide
MESSAGE MEANING ACTION REQUIRED
No message on display. Power
has been shut off to hot tub. GFCI
breaker is on but the control panel
is blank. System fuse(s) are blown.
The control panel will be disabled until power returns. System resets time of day
on each power-up. Hot tub settings are preserved. Call your store for service.
OHH or
HH
“Overheat”- The hot tub has shut
down. One of the sensors has
detected 118°F / 47.8°C at the
heater.
DO NOT ENTER THE WATER. Remove the Heatshield cover and allow water to
cool. Once the heater has cooled, reset by pushing any button. Check to see
if the knife valve on return side of the heater is closed, if closed ensure that all
knife valves are in the up or open position. If hot tub does not reset, shut off
power to the hot tub and call your Beachcomber store.
OHS or
OH
“Overheat”- The hot tub has shut down.
One of the sensors has detected that
the hot tub water is 110°F
/
43.3°C.
DO NOT ENTER THE WATER. Remove the hot tub Heatshield and allow water to cool.
At 107°F
/
41.7°C. the hot tub should automatically reset. Follow action required for
“OHH”. If hot tub does not reset, shut off power to the hot tub and call your store.
ICE or
IC
“Ice”- Potential freeze condition
detected.
No action required. The Pumps and blower will automatically activate
regardless of hot tub status.
25