Installation Guide

18 beamlabs.io 1-800-436-9186
CONNECTING POWER AND ALIGNING PHOTO EYE SAFETY SYSTEM
* DO NOT OPERATE OPENER AT THIS TIME *
Plug power head into a grounded outlet ONLY. If there
is no grounded outlet present, call a qualified electrician
to replace the outlet. Use of a surge protector is highly
recommended.
Invisible
Light Beam
Aligned
To prevent SERIOUS INJURY or DEATH from
electrocution or fire:
Power MUST be DISCONNECTED BEFORE
proceeding with permanent wiring procedures.
Garage door opener installation and wiring MUST
be in compliance with all local electrical and
building codes. Make sure the opener is ALWAYS
grounded.
NEVER use an extension cord, 2-wire adapter or
modify the power plug in any way to make it fit the
outlet.
To prevent SERIOUS INJURY or DEATH from a closing
garage door:
The photo eye safety system MUST be installed
BEFORE connecting power.
The photo eye safety system MUST be properly
connected and aligned BEFORE operating the
opener.
NOTICE:
The garage door opener cannot be programmed
and will not close the door until photo eye safety
system are installed and aligned.
When the photo eye safety system is properly
aligned green LED (emitter) will emit a steady green
light and the red LED (sensor) will emit a steady red
light. The path of the invisible light beam MUST NOT
be obstructed. No part of the garage door or any
hardware should interfere or block either sensor.
The emitter generates the invisible light beam, and
the sensor receives the invisible light beam.
Right
For Permanent Wiring ONLY
Wrong
Steady Red &
Green LED
Conduit with wire
Line (Black)
Neutral (White)
White
Black
(From Transformer)
Ground (Green/Yellow)
Ground Screw (Green)
Brown
Wire nut
Emitter
Green LED ON
Sensor
Red LED ON
WARNING
Green LED (emitter) will flash until it is aligned with
red LED (sensor). Red LED will not illuminate until it
is aligned with green LED.