Installation Guide

beamlabs.io 1-800-436-9186 21
CONNECTING STANDARD DOOR CONTROL (BU100)
Look in the box for:
*NOTE: Your opener will contain one of two door controls. Follow the instructions corresponding to the control provided.
WARNING
To prevent SERIOUS INJURY or DEATH from electrocution or
fire:
Be sure power is NOT connected BEFORE installing door
control.
Connect door control ONLY to 12 VOLT low voltage wires.
To prevent SERIOUS INJURY or DEATH from a closing garage
door:
Install door control within sight of garage door, at a
minimum height of 5 feet (1.5 m) so small children are not
able to reach it, and away from ALL moving parts of door.
NEVER permit children to operate or play with door
control or remote controls.
Activate garage door opener ONLY when door can
be seen clearly, is properly adjusted, and there are no
obstructions to door travel.
• ALWAYS keep a moving garage door in sight until
completely closed. NEVER cross path of moving garage
door.
Standard Door
Control
2 x Lag Screws
#6 x 1-3/8"
2 x Anchors
1/4" (6mm)
Connect the wire from the standard door control to the push button terminal on the rear panel of the power head.
Wire standard door control to
opener as shown.
Standard Door
Control
Bottom screw
Top screw
1. Strip 7/16 inch (11 mm) of insulation from wire and separate wires.
2. Connect one wire to each of the two screws on the back of the
door control. *DO NOT RECOMMEND USING PRE-EXISTING
WIRE*
3. Mark the location of bottom mounting hole and drill 5/32 inch hole.
4 Install the bottom screw and allow 1/8 inch (3 mm) to protrude
from wall. Note: Use anchors if mounting to drywall.
5. Position bottom hole of door control over the screw and slide
down into place.
6. Li actuation button and mark the top hole. Remove the door
control from wall and drill 5/32 inch hole for top screw.
7. Position bottom hole of door control over the screw and slide
down into place. Fasten the top screw.
Min. 5 feet
(1.52 m)
above floor