Installation Guide

24 beamlabs.io 1-800-436-9186
TRAVEL LIMIT ADJUSTMENT - DOWN LIMIT
Press and release “Limit” button twice, the red (DOWN) LED will illuminate. Press and hold the “Down” button
until door reaches desired close position.
Once the door is at the desired close position, press and release the “Limit” button once. The “OK” LED flashes
and turns off. The DOWN Limit has now been set.
To prevent SERIOUS INJURY or DEATH from
improper Force Adjustment:
YOU CANNOT adjust force manually to compensate
for binding or sticking of the garage door. Call
a qualified garage door service person to make
necessary adjustments in case of binding.
YOU CANNOT manually increase the force required
for closing the door.
Aer ANY adjustments, Safety Reversal Test MUST
be performed to ensure the door reverses on
contact with a 1-1/2 inch (3.8 cm) high object (2x4
laid flat).
Press and release
LIMIT twice
Press and hold DOWN
Desired DOWN limit
Press and release LIMIT just once
NOTICE:
Travel limits and auto force setting must be set for
the opener to work. All steps on pages 23-25 must
be followed.
WARNING