Installation Guide

beamlabs.io 1-800-436-9186 25
SETTING THE FORCE
Once UP and DOWN limits are set, ensure both UP and
DOWN LEDs are illuminated. *if necessary toggle “Limit”
button until both LEDs are illuminated*
Press and release the “Force” button once. Door will travel
one complete cycle followed by flashing of the “OK” LED
and 3 beeps. Programming is now complete.
The door will travel
UP automatically.
Door will then
travel DOWN
automatically.
Stop at UP limit for 2
seconds.
OK indicator (orange)
will flash with beeps,
Auto Force Setting is
completed.
Flash and 2
beeps
To prevent SERIOUS INJURY or DEATH from
improper Force Adjustment:
YOU CANNOT adjust force manually to compensate
for binding or sticking of the garage door. Call
a qualified garage door service person to make
necessary adjustments in case of binding.
YOU CANNOT manually increase the force required
for closing the door.
Aer ANY adjustments, Safety Reversal Test MUST
be performed to ensure the door reverses on
contact with a 1-1/2 inch (3.8 cm) high object (2x4
laid flat).
2 sec
NOTICE:
Travel limits and auto force setting must be set for
the opener to work. All steps on pages 23-25 must
be followed.
WARNING