Install Instructions

Y8611 Rev. E
Run a drain line from the evaporator coil drain to the
pump. Use the flexible plastic pipe where the code
permits. Insert the pipe 1” below the pump cover. Do not
install inlet drain line that would interfere with operation
of floats. Connect outlet tubing (copper or vinyl) to
discharge on pump. Do not run tubing vertical more than
is recommended by the lift on each unit. For good flow,
slant the horizontal run downward toward the drain.
Each CB25 comes standard with a check valve for
connecting to 3/8” O.D. copper tubing. Each CB50 unit
comes standard with a check valve for connecting to ½
O.D. copper tubing. A copper tube adapter is included
for vinyl hose hook-up.
PIPING
WIRING
LIMITED WARRANTY
These Beckett pumps are warranted to the user against defective material and workmanship under normal use, for a period of 1 year from the date of purchase by the original purchase. All
other Beckett products are warranted to the user against defective material and workmanship for 3 months from the date of purchase. Replacement liability in all events is limited to the
replacing or repairing at Beckett’s sole discretion of any part or parts, which are defective in material or workmanship. Proof of purchase is required on all claims in the form of invoice copy,
sales ticket, etc.
APPLICATION: Warranty covers only properly installed and maintained units. Warranty is limited to applications pumping fresh water at temperatures of 32°-98°F (0°-36°C), with a pH range
of 5 to 9. Beckett Corporation must approve other liquid applications and extreme temperature uses in advance in writing.
ADMINISTRATION: Warranty claims must be made by returning the defective part, freight prepaid, along with proof of purchase, to: Beckett Corporation, Customer Care Dept., Irving, TX.
Phone authorization is required prior to returning merchandise (972-871-8000). All items returned will be inspected to determine cause of failure before warranty is approved.
INSTALLATION and/or REMOVAL CHARGES: Warranty does not cover any costs associated with the installation or removal of products subject to warranty claims.
DISPOSITION: Beckett will make a good-faith effort for prompt disposition regarding any item in warranty, which proves to be defective. If products were damaged in transit, please file a claim
with the carrier.
DISCLAIMER: Any oral statements about the product made by the seller, the manufacturer, the representatives or any other parties, do not constitute warranties, should not be relied upon by
the user, and are not part of the contract for sale. Seller's and manufacturer's only obligation and buyer's and user's only remedy, shall be for the manufacturer to either replace and/or repair at
the manufacturer's sole discretion the Beckett product as described above. Neither seller nor the manufacturer shall be liable for any injury, loss or damage, direct, incidental or consequential
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss), arising from any cause
whatsoever, no matter whether based upon warranty, contract, negligence or other misuse, and the buyer and user agree that no other remedy shall be available to them. Before using, the
buyer and user shall determine the suitability of the product for the intended use, and assumes all risk and liability whatsoever in connection herewith. The warranty and remedy described in this
limited warranty is an EXCLUSIVE warranty and remedy. IN LIEU of any other warranty or remedy, expressed or implied, which other warranties and remedies are hereby expressly
EXCLUDED, including but not limited to any implied warranty of MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. This Warranty gives buyer and user specific legal rights,
and buyer and user may also have other rights that vary from state to state. Some states do not allow the exclusion or limitations of incidental or consequential damages, so the above limitation
or exclusion may not apply to you.
The wiring must comply with local codes.
WARNING
Turn the electric power off at the fuse box before making any line voltage connections.
MAINTENANCE AND TROUBLE
SHOOTING
1. Remove dirt that may collect in bottom sump.
2. Look at vinyl DISCHARGE LINE to see that it is open and water can pass through freely.
3. Always replace cover to keep electrical parts clear of dust and grime.
4. See item 7 of Introduction.
To test safety float switch, temporarily stop flow of discharge line by sharply bending vinyl tubing. Pour more water into pump
inlet. Water level will rise beyond high level of control float until safety float switch breaks the “Y” thermostat circuit shutting down
air conditioner condensing unit. Unbend the tube and the pump will empty the entire sump. Replace inlet line into pump inlet.
WIRING
DIAGRAM
FOR CB25
AND CB50.
Designated
Pump Lift
Copper Tube
Nut
Check Valve
Snap Ring
Ball-Cage
Vinyl Hose
Evaporator
(“A” Coil)
Pump
Micro Switch
Safety Micro Switch
Green Ground
Conn.
Terminal
Block
Voltage as
shown on
Name Plate
Attach to
“Y” on Relay
“Y” on Thermostat
NEC. Class 2
(Low Voltage)
Pump
Black
White
Green
Inner Ring
Ball
Adapter