Installation guide
General information
Hazard Definitions
indicates a hazardous situ-
ation, which, if not avoided,
will result in death or serious injury.
indicates a hazardous
situation, which, if not
avoided, could result in death or serious
injury.
CAUTION indicates a hazardous
situation, which, if not
avoided, could result in minor or moderate
injury.
Within the boundaries of the hazard warning, there will
be information presented describing consequences if the
warning is not heeded and instructions on how to avoid
the hazard.
Intended to bring special attention to
information, but not related to personal injury or property
damage.
Owner's Responsibility
Incorrect installation, adjustment,
and use of this burner could result in
severe personal injury, death, or sub-
stantial property damage from fire,
carbon monoxide poisoning, soot or explosion.
Contact a professional, qualified service agency for the
installation, adjustment and service of your oil heating
system. This work requires technical training, trade ex-
perience, licensing or certification in some states and the
proper use of special combustion test instruments.
Please carefully read and comply with the following
instructions:
• Never store or use gasoline or other flammable
liquids or vapors near this burner or appliance.
• Never attempt to burn garbage or refuse in this
appliance.
• Never attempt to light the burner/appliance by
throwing burning material into the appliance.
• Never attempt to burn any fuel not specified and
approved for use in this burner.
• Never restrict the air inlet openings to the burner
or the combustion air ventilation openings in the
room.
This manual contains information that applies to both AF and AFG burners. These burners may
appear to be basically identical, but there are differences in design and performance. Please review the comparison
chart below:
Feature AF AFG
Static Pressure Capability Conventional - Low range Enhanced - Medium range
Blower Wheel Design Standard strip Special tablock
Inlet Airflow Design Standard inlet bell Special airguide
ULAir Tube Combinations "F" Series ONLY "F" or "M" Series
Igniter Gaskets Baseplate/Barrier Optional, as specified Required, always specified
Low Firing Rate Baffle Not required Required, per specification
Figure 1. Burner label location
Generalm0del
Information
Serial number,-
including date code
Rating Information-
Approvalagency--
symbols
Primary group --
and fuel oH
Model" AFG"
Series 0il Burner
SERIAL NUMBER
000405-62736
IIIIIIlllilllHIIIIIIIlU
0.O0-3.00GPH,lo0V/S0HZ5O0
USTED @.
OIL BURNER NO. R-I00001
R,W,Beckett Corp.
_/o0,o_o
Uode_nt_eUSA
Fo_u_ w_hGrip1 _ 2
kppr_o_ulyi,19O0
MP1192 NB_O01 O00
MFR'SSE]-rlNGS
ATC: _O0XN
RIO0 _: 0,75-LO0GPH
sic Ptl:
NOZZLE: 1.0X 80B0tVN
P_P PO0: 1001,9
BJBS001 R00
000405-62736
4 ULTESTsoot
5 ULTOOTSP[C
6 ULTO0TSPEC
7 ULIEST SPEC
8 ULTEST SPO0
9 ULTF3,_r SPZC
Sto_en _0m_
NOPr_l BEC-O041
A_pted N.Y.C._Ek 21_-83-E
6104BAFG R04
-- R.W.Beckett
manufacturer's settings
-- R.W,BeckeKspecification
number and revision
--Con be cu_
individual specification
--State and local approvals
"'--........ /"
SK9890