Specifications

Beech Ovens Page 104 28/07/2011 (C)
RND-REC-RGO Manual (R1) Confidential and Proprietary
Phillips head screws
To remove the Tri-electrode
assembly, loosen and remove
the two (2) Phillips head
screws holding the Tri-
electrode.
Note: The Tri-
electrode is mounted
in a ceramic base
and is easily cracked if not
handled correctly. Always
check for cracks when
servicing this component.
Carefully remove the Tri-electrode and gently remove any
debris which may have built up around the Tri-electrode using a soft brush or rag.
Note: Be sure not to adjust the positioning of the Tri-electrode probes.
Positioning of these probes is critical for the correct function of the gas
system. See next page for correct positioning details.
As general maintenance, clear
any debris that may have
accumulated in the base of
blow back chute.