User manual

USER MANUAL FOR BEEM OUTDOORS, LLC. 20KW
SILENT STANDBY GENERATOR SET
30
1. Gas inlet: Connects the external fuel lines to the generator. The outer diameter is
¾” (19mm), and the internal diameter is 5/8” (15mm).
2. Gas filter: Will filter most impurities from the gas. The internal filtering element
helps to prevent carbon deposits from building up inside the fuel lines, engine, and
exhaust lines.
3. Solenoid valve: Included is an electrically controlled double solenoid valve and is
operated by the electronic control system. It uses a 12V DC drive solenoid winding coil
to produce a magnetic field which adjusts the sealed diaphragm upward or downward to
allow the gas to flow as needed.
4. Gas Pressure valve: Adjust the inlet gas using the negative pressure created by
the engine. This pressure is automatically reduced when absorbed by the engine. The
diaphragm will adjust upward or downward as needed. The position of the diaphragm
adjusts automatically applying to correct amount of pressure to the available gas flow as
needed to force the gas feed to insure proper engine performance.
5Switch valve: Allows selection of natural gas (NG) or liquid propane gas (LPG)
gas as fuel. The gas line diameters have been pre-determined to optimize the gas flow.
The flow of gas and operating performance of the gas system has been tested before
leaving the factory. Adjustment of this system or lines by a non-professional may alter
the flow of gas causing the engine not to start or run properly.
. Control System
The intelligent control system is the core of the generator control system. The
intelligent control system has an integrated and visual operational panel which includes
the ability to set and monitor various system functions. It can also display different
measured parameters, control parameters, and the generator operating status.
Sensors are located on the engine and generator to monitor liquid coolant
temperatures, oil temperatures, engine operating conditions, generator operating
condition, the quality of the electrical power supply, etc… It has the ability to switch to a
self-protection mode should abnormal operations be detected. A remote operation port is
available allowing trained professionals to set unique operating requirements.
Refer to the control panel user manual and the wiring diagram for a more detailed
description of the control system.