7263LED

Installation and Technical Information
BEGA
CSA certi ed to U.S. and Canadian standards. Suitable
for wet locations.
In the interest of product improvement, BEGA reserves the right to make technical changes without notice.
© Copyright BEGA-US 2014
Garden bollard

0$;
Anchorage post
Supply wiring
Bollard wiring
Set screws
Supply wiring
Luminaire 7263LED:
Housings: Garden bollard housing made of aluminum alloy with matte
safety glass. Anchorage post (supplied) made of galvanized steel.
Electrical: 3.4W LED luminaire, 5 total system watts, -30°C start
temperature. Integral 12V AC driver provided. Standard LED color
temperature is 3000K with an 85 CRI.
IMPORTANT: For use with magnetic landscape transformers ONLY.
Warranty: 3 year manufacturer warranty
Notice to Installer for 7263LED:
WARNING: LEDs are high-quality electrical components. Please avoid
opening upper electrical compartment and do NOT touch LED module.
WARNING: RISK OF ELECTRIC SHOCK. Install all luminaires 10 feet or
more from pool, spa or fountain.
1. Compatible for use with 12-24V AC input voltage.
2. Voltage must NOT drop below 10V.
3. Turn main power OFF before start of installation.
4. Low voltage wiring is intended for shallow burial - no more than 6 in.
7263LED installation:
1. Establish area for xture placement and prepare soil for
anchorage by digging a hole (12” maximum depth).
2. Dig a trench from the anchorage hole to the power source. Depth
of the trench will be determined by national, state, and local
codes.
3. Install at least 3” of pea gravel or similar in the bottom of the
anchorage hole for drainage.
4. Loosen (2) set screws on garden bollard to release anchorage post.
5. Bring 12V-24V supply wiring into the bottom of the anchorage post
and feed through to the top until there is 12” of cable coming up
through the top of the anchorage post.
6. Bury supply wiring cable in trench.
7. Place anchorage post into hole and ll in hole with packed soil,
making sure that the post is vertical and secure.
8. Make wire splices from supply wiring coming out of anchorage
post to bollard wiring coming down from bollard shaft. For
maximum wire run lengths, see table to the right.
9. Push splices into bollard shaft.
10. Mount bollard onto anchorage post until the bottom of the bollard
hits the ground. Tighten (2) set screws to secure bollard to
anchorage shaft.
11. Connect supply wiring to main power. Turn main power on.
Garden luminaire - low voltage
7263LED
Tools Required:
3mm hex key
Standard small slotted screwdriver
Digging tool
Protection Class: IP64
Weight: 6.3 lbs.
Dimensions
A: 4 3/8”
B: 27 1/2“
Lamp: Integral 3.2W LED Module
(No replacement necessary)
7263LED
3/5/2014
18 16 14 12 10
40 46 73 116 185 294
30 61 97 155 246 392
20 92 146 232 369 588
15 122 195 309 492 784
10 183 292 464 738 1176
5 366 585 928 1477 2353
WireSize(AWG)
Max.RunLength(ft)PerWireSize:2Voltdrop
Connected
LEDWatts
Replacement Parts:
LED Module LED-0234/830
LED Driver 75946
Cable (6 ft.) 86067

Summary of content (1 pages)