Datasheet
www.Amprobe.com
Data Sheet
Function Range Accuracy
Specifications (23 °C ± 5 °C, <75 % R.H. non-condensing), cont.
Capacitance
Ranges 40 nF, 400 nF, 4 µF, 40 µF, 400 µF
Accuracy 40 nF, 400 µF ranges: ± (3.0 % rdg + 10 dgts)
400 nF to 40 µF ranges: ± (3.0 % rdg + 5 dgts)
Resolution 0.01 nF
Temperature
Ranges -20 °C to 1300 °C, -4 °F to 2372 °F
Accuracy -20 °C to 10 °C: ± (2.0 % rdg + 4 °C )
10 °C to 200 °C: ± (1.0 % rdg + 3 °C )
200 °C to 1300 °C: ± (2.0 % rdg + 2 °C )
-4 °F to 50 °F: ± (2.0 % rdg + 8 °F)
50 °F to 400 °F: ± (1.0 % rdg + 6 °F)
400 °F to 2372 °F: ± (2.0 % rdg + 4 °F)
Resolution 1 °C, 1 °F
Frequency
Ranges 100 Hz, 1000 Hz, 10 kHz, 100 kHz, 1000 kHz, 10 MHz ± (0.1% rdg + 5 dgts)
Resolution 0.01 Hz
Duty Cycle
Ranges 0 to 90 %
Accuracy 5 V logic: ± (2.0% rdg + 10 dgts)
Resolution 0.01 %
Frequency Range 0 % to 10 %: 40 Hz to 990 Hz
10 % to 90 %: 40 Hz to 20 kHz
4 - 20 mA DC Current Test
Range 0 – 100 % ± (0.5 % + 5 dgts)
Resolution 0.01 %
dBm
Ranges -13 dBm to + 50 dBm
Accuracy 45 Hz to 5 kHz: ± (0.7 dB + 8 dgts)
5 kHz to 10 kHz: ± (2.5 dB + 8 dgts)
Resolution 0.01 dBm
Continuity
Audible Indication < 40 Ω
Diode Test
Test Current 0.5 mA (approximate)
Open Circuit Volts 3.0 V DC typical
Peak
AC Volts Accuracy 100 V, 750 V ranges: ± (3.0 + 200 dgts)
AC Current 1000 mV, 10 V ranges: unspecified ± (3.0 + 200 dgts)
Overload Protection
AC/DC Voltage 1000 V DC or 750 V AC RMS
AC/DC Current µA/mA input: F0.5 A /1000 V fast-blow ceramic 6.3 x 32 mm
10A input: F10 A /1000V fast-blow ceramic 10 x 38 mm