Instructions

14
Data Hold
2100-Beta: only voltage
measurement (12...690V AC/DC)
2100-Gamma: voltage and resistance
measurement, Non contact cable
break detector / EF
Measurement Area Illumination / Torch Light
White LED
Backlight
White LED
General Specifications
Operation time
(DT)
30 s
Recovery time 240 s
Operating
temperature
-15°C to +55°C
Storage
temperature
-15°C to +55°C
Humidity Max. 95% RH
Operating
altitude
Up to 2000 m
Safety rating
(overvoltage
category)
CAT IV / 600V, CAT III / 690V
(2100-Alpha / 2100-Beta)
CAT IV / 600V, CAT III / 1000V
(2100-Gamma)
Pollution degree 2
Protection
degree
IP 64
Safety
regulations
IEC 61243-3:2014,
EN 61243-3:2014,
DIN VDE 0682-401:2015
Approvals,
compliance
GS mark from TÜV Rheinland, CE
Power Supply Battery 2 x 1.5V (AAA/ IEC LR03)
Power
consumption
Approximately 90 mA
Battery lifetime
More than 10000 measurements
(<5 s / per measurement)
Dimensions
(HxWxD)
Approximately 280 x 78 x 35 mm
(11.0 x 3.1 x 1.4 in)
Weight Approximately 320 g (0.71 lb)
MAINTENANCE AND REPAIR
According to the operating instructions the voltage
tester do not require any special maintenance for
operation. However, if a malfunction occurs during
operation, the measurement has to be stopped and a
further measurement is not allowed. The unit has to be
tested at our factory service department. Except for the
replacement of the battery, any repair of the instrument
should be performed only by an Authorized Service Center
or by other qualified instrument service personnel.
WIf the instrument is not used for a prolonged period,
the batteries must be removed, as leaking batteries may
be hazardous and cause damages.