• Tests voltage without contact.
• Safety CAT IV 1000 V rated for a wide range of
applications including industrial, commerical,
and residential.
• Water-resistant IP65 rated for indoor and
outdoor use.
• Magnetic solenoid detection to diagnose
electromagnets and relays (NCV-1040-EUR only).
OPERATING INSTRUCTIONS
Turning the Voltage Probe ON
To turn the Voltage Probe on, momentarily press
the ON/OFF button. A continual single ash visually
indicates the Voltage Probe is active in default
voltage range (50 to 1000 V). Press the ON/OFF
button again to switch to high sensitivity
range (12 to 50 V for NCV-1030/1040-EUR only).
A continual double ash indicates the Voltage
Probe’s sensitivity range is at the 12 to 50 V range.
Turning the Voltage Probe OFF
Press and hold the ON/OFF button for longer
than two second to turn the Voltage Probe off. The
absence of ash at the tip indicates the Voltage
Probe is inactive.
Auto Power Off
To save battery life, the
NCV-1030/1040-EUR
are
enabled with an automatic power off feature. The
Voltage Probe will automatically power off after
approximately 3 minutes of non-use.
Checking for the Presence of AC Voltage
To test for the presence of AC voltage in a
receptacle, insert the tip of the Voltage Probe. To
test a wire, approach the wire with the tip of the
Voltage Probe. Switch between default (50 V to
1000 V AC) and high sensitivity (12 V to 50 V AC)
voltage range detection by short pressing the ON/
OFF button (NCV-1030/1040-EUR only). The LED at
the tip of the Voltage Probe will illuminate and
ash bright red and a buzzer will sound when AC
voltage is detected.
Note: High sensitivity range is optimized for 12 to
50 V range with a maximum indication up to 1000
V. Using the tester above 50 V in high sensitivity
range may affect polarity indication.
When operating the Voltage Probe, always
keep ngers behind the nger guard.