User manual

6
SPECIFICATIONS
Operating
Voltage Range
NCV-1020-EUR:
50-1000 Vac, 50-400 Hz
NCV-1030-EUR:
12-50 Vac, 50-1000 Vac, 50-400 Hz
NCV-1040-EUR:
12-50 Vac, 50-1000 Vac, 50-400 Hz
Voltage
Detection
(default
range)/
sensetivity
LED and buzzer indications at
approximately 5 mm (0.20 in)
distance from a wire carrying
230 Vac
Detection
of Magnetic
Field/
sensetivity
NCV-1040-EUR:
approximately >2.5 mT
Measuring
category
CAT IV 1000V
Ingress
protection
IP65
Temperature
Range
0 °C to 40 °C (32 °F to 104 °F),
≤ 80% RH
Storage
Conditions
-10 °C to 40 °C (14 °F to 104 °F),
≤ 85% RH
Operating
Altitude
≤ 2000 m (6561 ft)
Duty Cycle Continuous
Power Supply 2 x 1.5 V LR03 AAA batteries
Current
Consumption
Approximately 80 mA
Dimensions
(L x W x H)
156.2 x 23.5 x 27.5 mm
(6.14 x 0.92 x 1.08 in)
Weight
(with
batteries
installed)
NCV-1020-EUR: Approx. 58 g (0.12 lb)
NCV-1030-EUR: Approx. 60 g (0.13 lb)
NCV-1040-EUR:
Approx. 62 g (0.136 lb)
Safety
Compliance
IEC 61010-1 3rd Ed., UL 61010-1 3rd
Ed., UL 61010-2-030, CAN/CSA-C22.2
No.61010-1-12, CAN/CSA-C22.2 No.
61010-2-030-12 to CAT IV 1000 V,
Pollution degree 2, IP65