18
Resistance
Range Accuracy
600.0 Ω, 6.000 kΩ, 60.00 kΩ ± (1.0 % + 5 LSD)
Open Circuit Voltage: 1.0VDC typical
Capacitance
Range Accuracy
1)
200.0 μF, 2500 μF ± (2.0 % + 4 LSD)
1)Accuracy with film capacitor or better
Diode
Range Accuracy
2.000 V ± (1.5 % + 5 LSD)
Test Current: 0.3mA typically
Open Circuit Voltage: < 3.5VDC typically
DC μA
Range Accuracy Burden Voltage
200.0 μA, 2000 μA ± (1.0 % + 5 LSD) 3.5 mV/μA
Temperature
Range Accuracy
-40.0 °C to -10.0 °C ±(1% + 1.5 °C)
> -10 °C to 99.9 °C ±(1% + 0.8 °C)
100 °C to 400 °C ±(1% + 1 °C)
-40.0 °F to 14.0 °F ±(1% + 3.0 °F)
> 14.0 °F to 99.9 °F ±(1% + 1.5 °F)
100 °F to 752 °F ±(1% + 2 °F)
K-type thermocouple accuracy tolerances not included
Precise Low Current AC
Range Accuracy
1) 2) 3)
0.00 A to 20.00 A ± (1.5 % + 5 LSD) @ 40 Hz to 100 Hz
± (2.0 % + 5 LSD) @ 100 Hz to 400 Hz
>20.00 A to 60.00 A ± (3.0 % + 5 LSD) @ 40 Hz to 100 Hz
± (3.0 % + 5 LSD) @ 100 Hz to 400 Hz
1) Induced error from adjacent current-carrying conductor: < 0.02 A/A
2) Specified with relative zero
mode applied to offset the non-zero
residual readings, if any.
3) Add 10 LSD to the specified accuracy @ < 4 A