User Manual

19
Precise Low Current DC
Range Accuracy
1) 2) 3)
0.00 A to 20.00 A ± (1.5 % + 5 LSD)
>20.00 A to 60.00 A ± (3.0 % + 5 LSD)
1) Induced error from adjacent current-carrying conductor: < 0.02 A/A
2) Specified with DC-zero mode applied to offset the non-zero residual
readings, if any
3) Add 10 LSD to the specified accuracy @ < 4 A
Precise Low Current DC+AC
Range Accuracy
1) 2) 3)
0.00 A to 20.00 A ± (2.0 % + 7 LSD) @ DC, 40 Hz to 100 Hz
± (2.2 % + 7 LSD) @ 100 Hz to 400 Hz
>20.00 A to 60.00 A ± (3.0 % + 7 LSD) @ DC, 40 Hz to 100 Hz
± (3.0 % + 7 LSD) @ 100 Hz to 400 Hz
1) Induced error from adjacent current-carrying conductor: < 0.01 A/A
2) Specified with DC-zero mode applied to offset the non-zero residual
readings, if any
3) Add 10 LSD to the specified accuracy @ < 4 A
AC Current
Range Accuracy
1)
60.00 A
2)
, 600.0 A, 1000 A
3)
± (1.8 % + 5 LSD) @ 40 Hz to 100 Hz
60.00 A
2)
, 600.0 A, 1000 A
3)
± (2.2 % + 5 LSD) @ 100 Hz to 400 Hz
1) Induced error from adjacent current-carrying conductor: < 0.02 A/A
2) Add 10 LSD to the specified accuracy @ < 9 A
3) Maximum crest factor < 1.4:1 at full scale & < 2.8:1 at half scale
DC Current
Range Accuracy
1) 2) 3)
60.00 A
3)
, 600.0 A, 1000 A ± (1.8 % + 5 LSD)
1) Induced error from adjacent current-carrying conductor: < 0.02 A/A
2) Specified with DC-zero mode applied to offset the non-zero residual
readings, if any
3) Add 10 LSD to the specified accuracy @ < 9 A
DC+AC Current
Range Accuracy
1) 2)
60.00 A
3)
, 600.0 A, 1000 A
4)
± (2.2 % + 7 LSD) @ DC, 40 Hz to 100 Hz
60.00 A
3)
, 600.0 A, 1000 A
4)
± (2.5 % + 7 LSD) @ 100 Hz to 400 Hz
1) Induced error from adjacent current-carrying conductor: < 0.08 A/A