Datasheet

PM 55 Specifications cont.
Frequency
Range Accuracy Specified at
10.00 Hz - 30.00 kHz
1, 2
± (0.5 %+4 dgt) < 2 0 V Sine-rms
1
0.00 Hz - 999.9 Hz ± (0.5 %+4 dgt) < 600 V Sine-rms
1
Sensitivity (Sine-rms): Hz in A
uto-V ( position:> 3 V
2
Line-level Hz in V position: @6.000 V ac r
ange: > 3 V; @60.00 V ac range: > 6 V; @600.0 V ac range: > 60 V
DC µA Current
Range Accuracy Burden voltage
400.0 µA ± (1.5 %+3 dgt) 6 mV/µA
2
000 µA ± (1.2 %+3 dgt) 6 mV/µA
AC µA Current
Range Accuracy Burden voltage
400.0 µA ± (2.0 %+3 dgt) 6 mV/µA
2000 µA ± (1.5 %+3 dgt) 6 mV/µA
VolTect
Typical voltage Bar graph indication
15 V to 55 V
30 V to 85 V – –
55 V to 145 V – – –
85 V to 190 V – – – –
above 120 V – – – – –
Indication Bar graph segments & audible beep tones proportional to field strength
Detection frequency 50/60 Hz
Detection antenna Top left corner of the meter
Audible Continuity Tester (600 range)
Open circuit voltage 0.4 V dc typical
Audible threshold 50 to 300
Diode Test
Diode test current 0.48 mA
Open circuit voltage < 1.6 V dc
General Specifications
Displa
y and update r
ate
3-5/6 digits 6000 counts; Updates 5 per second nominal
Oper
ating temper
ature
0 ˚C - 40 ˚C
Relative humidity Max. 80 % R.H. up to 31 °C, decreasing linearly to 50 % R.H. at 40 ˚C
Altitude Operating below 2000 m
Stor
age temper
atur
e
-2
0 ˚C ~ 60 ˚C, < 80 % R.H. (with battery r
emo
v
ed)
Temperature coefficient Nominal 0.15 x (specified accuracy)/ ˚C @ (0 ˚C ~ 18 ˚C or
28 ˚C ~ 40 ˚C), or otherwise specified
Sensing A
v
er
age sensing
Overload protection 600 V dc and V ac rms
Low battery Below approx. 2.4 V
Power supply 3 V standard button battery x 1 (IEC-CR2032; ANSI-NEDA-5004LC)
Power consumption (typical)
6 mA for voltage functions on Auto-V W position & 2 mA for other functions
Automatic Power Off
(APO) timing Idle for 3 minutes
APO consumption (typical) 2.2
µ
A
Dimension/Weight
L 113 mm x W 53 mm x H 10.2 mm (4.4 x 2.1 x 0.4 in)/Approx. 78 gm (3 oz)
Special featur
es
A
utoT
ect™ (Automatic V &
selection) and V
olT
ect™ (Electric Field Detection)
Agency approvals CE, cULus
Safety Meets IEC61010-1, UL61010B-1, CAN/CSA-C22.2 No. 1010.1-92,
CA
T II 600 V and CA
T III 300 V, Pollution Degree 2, Class 2
E.M.C. Meets EN61326
Included
A
c
cess
or
ies
H-PM protective holster, VC3 zippered carrying case, battery installed and User’s manual.
PM 55
The compact precision DMM with AutoTect
and VolTect
Meterman Test Tools
website: www.metermantesttools.com
email: info@metermantesttools.com
6920 Seaway Blvd.
Everett, WA 98203
fax: 425-446-4882
tel: 877-596-2680
Meterman Test Tools Europe
P.O. Box 1186
560
2 BD Eindho
v
en
The Netherlands
©2
004 Meterman T
est T
ools
. All rights r
eserved.
Printed in U.S.A. 8/2004 2277165 D-US-N Rev A
Meterman.
The right tool for the job
Compact Digital Multimeter with AutoTect
and VolTect
Electrical noise or intense electromagnetic fields
in the vicinity of the equipment may disturb
the measurement circuit. Measuring instru-
ments will also respond to unwanted signals
that may be present within the measurement
circuit. Users should exercise care and take
appropriate precautions to avoid misleading
r
esults when making measur
ements in the
presence of electronic interference.