TDS

TECHNICAL DATA SHEETTECHNICAL DATA SHEET
This information is provided “as is” and no representations or warranties, either express or implied, of merchantability, tness for a particular purpose or of any other
nature are made with respect to this information or to any product referred to in this information. For SDS or to consult with a Behr Certied Coatings Professional, call
1-800-854-0133 Ext. 2 (U.S.A. only) or visit behr.com. ©2020 Behr Process Corporation, Santa Ana, CA 92705 U.S.A.
A primer coat may be needed on some surfaces. See SYSTEM RECOMMENDATIONS for details.
*For details visit behr.com/marqueeguarantee.
Revised 4/2020
1 of 2
EXTERIOR FLAT PAINT
NO. 4450 ULTRA PURE WHITE®
PRODUCT INFORMATION
BEHR MARQUEE® Exterior Flat Paint is our most advanced exterior paint & primer
that delivers exceptional durability and
weather resistance. It provides excellent resistance to dirt and fading, as well as resists rain as early as 60 minutes after
application. It also features one-coat hide guaranteed* in colors from the MARQUEE Exterior One-Coat Collection.
RECOMMENDED USES:
Use on properly prepared, primed or previously painted exterior surfaces such as:
• Stucco • Concrete • Masonry • Concrete Masonry Units • Brick
• Fiber Cement • Wood • Engineered Wood • Steel • Galvanized Steel
• Aluminum • Other Ferrous Metals • Other Non-Ferrous Metals • Architectural Plastics
PRODUCT SPECIFICATIONS:
Tint Bases/Max Tint Load:
No. 4450 Ultra Pure White 128  oz / 2  oz
No. 4454 Medium Base 120  oz / 10  oz
No. 4453 Deep Base 116  oz / 14  oz
Sheen: 0-6 @ 85°
Resin Type: 100% Acrylic
Weight per Gallon: 11.4 lb
% Solids by Volume: 45% ± 2%
% Solids by Weight: 58% ± 2%
VOC: <50 g/L
Flash Point: N/A
Viscosity: 100-110 KU
Recommended Film Thickness:
Wet: 6.4 mils / Dry: 2.9 mils @ 250 sq ft/gal
Wet: 4.0 mils / Dry: 1.8 mils @ 400 sq ft/gal
Coverage: 250-400 sq ft/gal depending on application
method and substrate porosity. Does not include the loss of
material from spraying.
APPLICATION:
Brush: Nylon/polyester
Roller: 3/8" – 3/4" nap roller cover, depending on surface
texture
Airless Spray:
Tip: .015"- .021"
Filter: 60 mesh
Fluid Pressure: 1,400 - 2,400 psi
Thinning: Do not thin if using a roller or brush; however, if
using a sprayer and thinning is required, thin with water at a
rate of no more than 1/2 pint per gallon.
Dry Time: @ 77°F & 50% RH
To Touch: 1 hour
To Recoat: 2 hours (3 hours for deep base)
Full Cure: 4 weeks
Dry times are temperature, humidity, and lm thickness
dependent.
SURFACE PREPARATION:
All surfaces must be clean, free of dust, chalk, oil, grease,
wax, polish, mold and mildew stains, loose and peeling
paint, rust and all other foreign substances.
New Wood: Remove mill glaze with sandpaper or use a
product such as BEHR PREMIUM® All-In-One Wood Cleaner
No. 63 to open the pores of the wood and follow all label
instructions. For severe stains caused by mold, mildew,
algae and fungus, apply a mildew stain removing product.
Set nails and ll holes, scratches, and gouges with the
appropriate wood ller and let dry completely. Remove all
dust with a wiping cloth. Fill all gaps with a 100% acrylic,
siliconized, paintable caulking and allow to dry completely.
Patched and lled surfaces should be sanded smooth
and dusted clean prior to coating. WARNING! Sanding or
scraping pressure treated lumber may be hazardous; wear
appropriate protection.
New Masonry: The pH must be 10 or lower prior to
coating. Smooth masonry may require an adequate prole
for adhesion. For all other smooth trowel concrete, create
an adequate prole for adhesion using a product such as
muriatic acid etcher or with mechanical means. Remove all
loose aggregate and debris. Prime the area with an alkali-
resistant primer.
Steel: Minimum surface preparation is Hand Tool Cleaning
in accordance with SSPC-SP2. Remove all oil and grease from
the surface with a solvent in accordance with SSPC-SP1.
For optimal performance, use Commercial Blast Cleaning
in accordance with SSPC-SP6. Prime the area with a rust-
inhibitive primer the same day as cleaned.
Galvanized Steel: Solvent clean new galvanized metal in
accordance with SSPC-SP1 to remove oil and grease from
the surface. Pre-treat with a phosphoric acid solution or
a commercially-available etching solution. Galvanized
metal that has been passivated with chromates or silicates
may require brush blasting in accordance with SSPC-SP16
to remove these treatments. Rusty galvanizing requires a
minimum of Hand Tool Cleaning in accordance with SSPC-
SP2. Prime the area the same day as cleaned.
Shop-Primed Steel: As there is potential for many forms
of contamination during storage and transport, a thorough
cleaning is always recommended for shop-primed surfaces.
Paint exposed areas, i.e., where shop primer is abraded, with
the same material as used for shop priming to comply with
SSPC-PA 1 for touching up shop-primed surfaces.
Note: Assess the integrity of the shop primer prior to
application of subsequent coatings. Review all coatings
intended for the project and conrm the compatibility
between shop and eld-applied coatings.
Aluminum: Remove all oil and grease from the surface with
a solvent in accordance with SSPC-SP1. Prime the area the
same day as cleaned.
Stain-Blocking: After priming, test for stain bleed-through
by applying the topcoat to a small section. If the stain bleeds
through the topcoat, apply a second coat of primer and
test again before topcoating the entire area. If bleeding
continues, primer may need a longer dry time before
applying topcoat.
Previously Painted Surfaces: Remove all loose and
peeling paint and all other foreign substances. Clean any
dirt and grease by scrubbing the surface with a detergent
and water solution, followed by a thorough rinsing with
clean water. Set nails and ll holes, scratches, and gouges
with the appropriate wood ller and let dry completely.
Remove all dust with a tack or wiping cloth. Fill all gaps with
a 100% acrylic, siliconized, paintable caulking, and allow to
completely dry prior to coating.
Glossy Surfaces: For maximum adhesion, sand the surface
thoroughly to provide a rough surface before coating.
COMPLIES WITH THE BELOW AS OF 4/1/2020
SCAQMD YES LADCO YES
CARB SCM 2007 YES AIM YES
OTC Phase II YES MPI 10
OTC YES

Summary of content (2 pages)