TDS

TECHNICAL DATA SHEETTECHNICAL DATA SHEET
EXTERIOR FLAT PAINT
NO. 4450 ULTRA PURE WHITE®
PRODUCT INFORMATION
BEHR MARQUEE® Exterior Flat Paint delivers exceptional durability and weather resistance. It provides excellent resistance to
dirt and fading, while standing up to rain as early as 60 minutes after application. It also features one-coat hide guaranteed*
in colors from the exclusive MARQUEE Exterior One-Coat Collection.
RECOMMENDED USES:
Use on properly prepared, primed or previously painted exterior surfaces such as:
• Stucco • Concrete • Masonry • Concrete Masonry Units • Brick
• Fiber Cement • Wood • Engineered Wood • Steel • Galvanized Steel
• Aluminum • Other Ferrous Metals • Other Non-Ferrous Metals • Architectural Plastics
PRODUCT SPECIFICATIONS:
Tint Bases/Max Tint Load:
No. 4450 Ultra Pure White® 128  oz / 2  oz
No. 4454 Medium Base 120  oz / 10  oz
No. 4453 Deep Base 116  oz / 14  oz
Sheen: 0 – 6 @ 85°
Resin Type: 100% Acrylic
Weight per Gallon: 11.4 lb
% Solids by Volume: 45% ± 2%
% Solids by Weight: 58% ± 2%
VOC: <50 g/L
Flash Point: N/A
Viscosity: 100 – 110 KU
Recommended Film Thickness:
Wet: 6.4 mils / Dry: 2.9 mils @ 250 sq ft/gal
Wet: 4.0 mils / Dry: 1.8 mils @ 400 sq ft/gal
Coverage: 250 – 400 sq ft/gal depending on application
method and substrate porosity. Does not include the loss of
material from spraying.
APPLICATION:
Brush: Nylon/polyester
Roller: 4/8" – 4/4" nap roller cover, depending on surface
texture
Airless Spray:
Tip: .015" – .021"
Filter: 60 mesh
Fluid Pressure: 1,400 – 2,400 psi
Thinning: Do not thin if using a roller or brush; however, if
using a sprayer and thinning is required, thin with water at a
rate of no more than 1/2 pint per gallon.
Dry Time: @ 77°F & 50% RH
To Touch: 1 hour
To Recoat: 2 hours (3 hours for deep base)
Full Cure: 4 weeks
Dry times are temperature, humidity, and lm thickness
dependent.
SURFACE PREPARATION:
All surfaces must be clean, free of dust, excessive chalk,
oil, grease, wax, polish, mold and mildew stains, loose and
peeling paint, rust and all other foreign substances.
Wood: Remove mill glaze with sandpaper or use a product
such as BEHR PREMIUM® All-In-One Wood Cleaner No. 63 to
open the pores of the wood and follow all label instructions.
For severe stains caused by mold, mildew, algae and fungus,
apply a mildew stain removing product. Set nails and ll
holes, scratches, and gouges with the appropriate patching
material and let dry completely. Remove all dust with a
wiping cloth. Fill all gaps with a 100% acrylic, siliconized,
paintable caulking and allow to dry completely. Patched and
lled surfaces should be sanded smooth and dusted clean
prior to coating. WARNING! Sanding or scraping pressure
treated lumber may be hazardous; wear appropriate
protection.
Masonry: Allow to cure for 30 days. The pH must be 10 or
lower prior to coating. Remove bond breakers and all form
release and curing agents. Smooth masonry may require an
adequate prole for adhesion. Remove all loose aggregate
and debris. If painting cannot wait 30 days or pH level is
above 10, allow the surface to cure 7 days and prime the
surface with an alkali-resistant primer.
Steel: Minimum surface preparation is Hand Tool Cleaning
in accordance with SSPC-SP2. Remove all oil and grease from
the surface with a solvent in accordance with SSPC-SP1.
For optimal performance, use Commercial Blast Cleaning
in accordance with SSPC-SP6. Prime the area with a rust-
inhibitive primer the same day as cleaned.
COMPLIES WITH THE BELOW AS OF 4/1/2023
SCAQMD YES LADCO YES
CARB SCM 2007 YES AIM YES
OTC Phase II YES MPI 10
OTC YES
Galvanized Steel: Solvent clean new galvanized metal in
accordance with SSPC-SP1 to remove oil and grease from
the surface. Pre-treat with a phosphoric acid solution or
a commercially-available etching solution. Galvanized
metal that has been passivated with chromates or silicates
may require brush blasting in accordance with SSPC-SP16
to remove these treatments. Rusty galvanizing requires a
minimum of Hand Tool Cleaning in accordance with SSPC-
SP2. Prime the area the same day as cleaned.
Shop-Primed Steel: As there is potential for many forms
of contamination during storage and transport, a thorough
cleaning is always recommended for shop-primed surfaces.
Paint exposed areas, i.e., where shop primer is abraded, with
the same material as used for shop priming to comply with
SSPC-PA 1 for touching up shop-primed surfaces.
Note: Assess the integrity of the shop primer prior to
application of subsequent coatings. Review all coatings
intended for the project and conrm the compatibility
between shop and eld-applied coatings.
Aluminum: Remove all oil and grease from the surface with
a solvent in accordance with SSPC-SP1. Prime the area the
same day as cleaned.
Stain-Blocking: After priming, test for stain bleed-through
by applying the topcoat to a small section. If the stain bleeds
through the topcoat, apply a second coat of primer and
test again before topcoating the entire area. If bleeding
continues, primer may need a longer dry time before
applying topcoat.
Previously Painted Surfaces: Remove all loose and
peeling paint and all other foreign substances. Clean any dirt
and grease by scrubbing the surface with a detergent and
water solution, followed by a thorough rinsing with clean
water. Set nails and ll holes, scratches, and gouges with the
appropriate patching material. Let dry completely and sand
smooth. Remove all dust with a tack or wiping cloth. Fill all
gaps with a 100% acrylic, siliconized, paintable caulking,
and allow to completely dry prior to coating.
Glossy Surfaces: For maximum adhesion, sand the surface
thoroughly to provide a rough surface before coating.
This information is provided “as is” and no representations or warranties, either express or implied, of merchantability, tness for a particular purpose or of any other nature
are made with respect to this information or to any product referred to in this information. For SDS or to consult with a Behr Paint Company representative,
call 1-800-854-0133 Ext. 2 (U.S.A. only) or visit behr.com. ©2023 Behr Process Corporation, Santa Ana, CA 92705 U.S.A.
A primer coat may be needed on some surfaces. See SYSTEM RECOMMENDATIONS for details.
*
For details visit behr.com/marqueeguarantee.
Revised 4/2023