TDS

TECHNICAL DATA SHEET
This information is provided "as is" and no representations or warranties, either expressed or implied, of merchantability, tness for a particular purpose or of any other
nature are made with respect to this information or to any product referred to in this information. For MSDS or to consult with a Behr Certied Coatings Professional,
call 1-800-854-0133 Ext. 2 (U.S.A. only). ©2017 Behr Process Corporation Santa Ana, CA 92704 U.S.A.
Revised 1/2017
1 of 2
STAINBLOCKING CEILING PAINT
NO. 5558 ULTRA PURE WHITE®
PRODUCT INFORMATION
BEHR PREMIUM PLUS ULTRA® Stain-Blocking Ceiling Paint is a premium quality, low VOC paint & primer in one coating that
will change the way you paint ceilings. Its performance-driven formulation blocks most household and water stains and
dries to form a mildew resistant lm. This exciting product, featuring advanced NANOGUARD® technology, provides an extra
protective shell that oers excellent stain resistance, with great touch up, coverage and hide, creating a STAYS LOOKING NEW
LONGER® nish. It is ideal for use in moisture-prone areas. The at sheen hides minor surface imperfections and can be
tinted to light hues.
RECOMMENDED USES:
On properly prepared coated and uncoated interior ceilings:
• Drywall/Gypsum Board
• Plasterboard
• Cured plaster
PRODUCT SPECIFICATIONS:
Tint Bases/Max Tint Load:
No. 5558 128 oz. / 2 oz.
Gloss: < 10 @ 60°
Sheen: 0-3 @ 85°
Resin Type: 100% Styrene Acrylic
Weight per Gallon: 11.8 lbs.
% Solids by Volume: 46%
% Solids by Weight: 61%
VOC: <50 g/L
Flash Point: N/A
Viscosity: 105-115 KU
Recommended Film Thickness:
Wet: 6.4 mils / Dry: 2.9 mils @ 250 Sq. Ft./Gal.
Wet: 4.0 mils / Dry: 1.8 mils @ 400 Sq. Ft./Gal.
Coverage: 250-400 Sq. Ft./Gal. depending on application
method and substrate porosity. Does not include the loss of
material from spraying.
APPLICATION:
Brush: Nylon/polyester
Roller:
Smooth Surface: 3/8" - 1/2" nap
Rough Surface: 1/2" - 3/4" nap
Airless Spray: At packaged consistency
Tip: .015"- .019"
Filter: 60 mesh
Thinning: (If required) No more than 1/2 pint
of water per gallon.
Dry Time: @ 77° & 50% RH
Longer dry time may be required in cooler temperatures
and higher humidity.
To Touch: 30 minutes
To Recoat: 1 hour
Full Cure: 4 weeks
SURFACE PREPARATION:
Remove all dust with a damp cloth, allow to dry. Allow new
plaster to cure for 30 days before priming. Make sure that
there are no active water problems and that any previous
water damage is fully dry. Use a product such as
BEHR PREMIUM PLUS ULTRA Stain-Blocking Ceiling Paint
as a primer for repaired or uncoated surfaces. Lock in
stains with a product such as BEHR PREMIUM PLUS ULTRA
Stain-Blocking Ceiling Paint as a spot primer. For heavy
stains, test for stain bleed-through by applying a product
such as BEHR PREMIUM PLUS ULTRA Stain-Blocking
Ceiling Paint as a topcoat to a small section. If the stain
bleeds through the topcoat, spot prime another coat to
the stained area and test again before top-coating the
entire ceiling. If bleeding continues, a longer dry time is
needed before topcoating. For drastic color changes,
apply a primer coat of a product such as BEHR PREMIUM
PLUS ULTRA Stain-Blocking Ceiling Paint if needed.
New Drywall: All drywall surfaces should be suciently
sanded smooth. Remove any remaining drywall dust prior
to priming. Allow all drywall compounds to be completely
dry prior to coating. Previously Painted Drywall: Remove
all loose and peeling paint and all other foreign substances.
Clean any dirt and grease by scrubbing the surface with
a detergent and water solution, followed by a thorough
rinsing with clean water. Set nails and ll holes, scratches,
and gouges with the appropriate spackling material.
Let dry completely and sand smooth. Remove all dust with
a wiping cloth. Fill all gaps with a 100% acrylic, siliconized,
paintable caulking, and allow to completely dry prior to
coating. Glossy Surfaces: For maximum adhesion,
sand the surface thoroughly before coating.
Wood: WARNING! Sanding or scraping pressure treated
lumber may be hazardous; wear appropriate protection.
New Plaster: New plaster should be thoroughly dried out and
cured for a minimum of 30 days before painting. When cured,
clean using a mixed solution of one part vinegar and one part
water to remove eorescence and neutralize. Previously
Painted Plaster: Remove all loose and peeling paint and all
other foreign substances. Clean any dirt and grease by scrubbing
the surface with a detergent and water solution, followed by
a thorough rinsing with clean water. Set nails and ll holes,
scratches, and gouges with the appropriate spackling material.
Let dry completely and sand smooth. Remove all dust with a
tack or wiping cloth. Fill all gaps with a 100% acrylic, siliconized,
paintable caulking, and allow to completely dry prior to coating.
Glossy Surfaces: For maximum adhesion, sand the surface
thoroughly before coating.
Stain-blocking: After priming, test for stain bleed-through
by applying the topcoat to a small section. If the stain bleeds
through the topcoat, apply a second coat of primer and
test again before top-coating the entire area. If bleeding
continues, a longer dry time of the primer may be needed
before top-coating.
WARNING! If you scrape, sand or remove old paint,
you may release lead dust. LEAD IS TOXIC. Contact the
National Lead Information Center at 1-800-424-LEAD
or visit www.epa.gov/lead.
COMPLIES WITH THE BELOW AS OF 1/1/2017
SCAQMD YES LEED v.3 (2009)
YES
CARB YES LEED v.4
YES
OTC YES GREENGUARD® YES
LADCO YES CHPS YES
AIM YES
This coating conforms to USDA regulatory requirements
for incidental food-contact materials intended for use on
surfaces not in direct contact with food, such as walls, oors
and ceilings.
Please visit www.usgbc.org/LEED for additional details.
GREENGUARD is a registered trademark of UL Company.

Summary of content (2 pages)