TDS

TECHNICAL DATA SHEETTECHNICAL DATA SHEET
INTERIOR FLAT PAINT
NO. 1050 ULTRA PURE WHITE®
PRODUCT INFORMATION
BEHR PREMIUM PLUS® Interior Flat Paint is a 100% acrylic paint & primer
that contains an antimicrobial agent to help
protect the surface of the paint film from mold and mildew. This easy-clean finish provides excellent touch-up, exceptional
durability and hide with a non-reflective matte appearance. Low odor formula.
RECOMMENDED USES:
Ideal for properly prepared coated and uncoated interior substrates such as:
• Drywall/Gypsum Board • Plaster • Concrete • Masonry • Brick
• Concrete Masonry Units • Wood • Engineered Wood • Steel • Galvanized Steel
• Aluminum • Other Ferrous Metals • Other Non-Ferrous Metals • Architectural Plastics
COMPLIES WITH THE BELOW AS OF 4/1/2020
SCAQMD Super
Compliant Coating
YES LEED® v.4
YES
SCAQMD YES MPI 53,143
CARB SCM 2007 YES MPI X-GREEN 53,143
OTC Phase II YES GREENGUARD®
#
YES
OTC YES CHPS YES
LADCO YES NAHB/ICC NGBS YES
AIM YES
This coating conforms to USDA regulatory requirements
for incidental food-contact materials intended for use
on surfaces not in direct contact with food, such as walls,
oors and ceilings.
Meets SCAQMD “super-compliant” VOC standard of <10
g/L.
Please visit www.usgbc.org/LEED for additional details.
#
GREENGUARD is a registered trademark of UL Company.
PRODUCT SPECIFICATIONS:
Tint Bases/Max Tint Load:
No. 1050 Ultra Pure White 128  oz / 2  oz
No. 1400 Medium Base 120  oz / 10  oz
No. 1300 Deep Base 116  oz / 14  oz
Pre-mixed colors:
No. 1012 Swiss Coee
No. 1052 White
Gloss: 0-4 @ 6
Sheen: 0-4 @ 85°
Resin Type: 100% Acrylic
Weight per Gallon: 12.1 lb
% Solids by Volume: 43% ± 2%
% Solids by Weight: 61% ± 2%
VOC: <5 g/L
ZERO VOC
This product, like most Zero VOC paints, emits very low
amounts of VOCs.
Most emissions occur during painting and for 48 hours
after. Some continue for two weeks or longer.
While VOC emissions are very low, sensitive groups
such as babies and asthma/allergy suerers should
minimize exposure.
Flash Point: N/A
Viscosity: 100-110 KU
Recommended Film Thickness:
Wet: 6.4 mils / Dry: 2.8 mils @ 250 sq ft/gal
Wet: 4.0 mils / Dry: 1.7 mils @ 400 sq ft/gal
Coverage: 250-400 sq ft/gal depending on application
method and substrate porosity. Does not include the loss
of material from spraying.
APPLICATION:
Brush: Nylon/polyester
Roller: 3/8” - 3/4” nap roller cover, depending on surface
texture
Airless Spray:
Tip: .015”- .019”
Filter: 60 mesh
Fluid Pressure: 1,400 - 2,400 psi
Thinning: Do not thin if using a roller or brush; however, if
using a sprayer and thinning is required, thin with water at
a rate of no more than 1/2 pint per gallon.
Dry Time: @ 77°F & 50% RH
To Touch: 1 hour
To Recoat: 2 hours
Full Cure: 4 weeks
Dry times are temperature, humidity, and lm thickness
dependent.
SURFACE PREPARATION:
All surfaces must be clean, free of dust, chalk, oil, grease, wax,
polish, mold and mildew stains, loose and peeling paint, rust
and all other foreign substances.
New Drywall:
All drywall surfaces should be suciently
sanded smooth. Remove any remaining drywall dust prior to
priming. Allow all drywall compounds to be completely dry
prior to coating.
New Wood:
Remove mill glaze with sandpaper or use a
product such as BEHR PREMIUM® All-In-One Wood Cleaner
No. 63 to open the pores of the wood and follow all label
instructions. For severe stains caused by mold, mildew, algae
and fungus, apply a mildew stain removing product. Set nails
and ll holes, scratches, and gouges with the appropriate
wood ller and let dry completely. Remove all dust with a
wiping cloth. Fill all gaps with a 100% acrylic, siliconized,
paintable caulking and allow to dry completely. Patched and
lled surfaces should be sanded smooth and dusted clean
prior to coating.
New Masonry:
Allow to cure for 30 days. The pH must be 10
or lower prior to coating. Remove bond breakers and all form
release and curing agents. Smooth masonry may require an
adequate prole for adhesion. Remove all loose aggregate
and debris. If painting cannot wait 30 days or pH level is
above 10, allow the surface to cure 7 days and prime the
surface with an alkali-resistant primer.
New Plaster:
New plaster should be thoroughly dried out
and cured for a minimum of 30 days before painting. When
cured, clean using a mixed solution of one part vinegar and
one part water to remove eorescence and neutralize. Prime
the area with an alkali-resistant primer.
Steel:
Minimum surface preparation is Hand Tool Cleaning
in accordance with SSPC-SP2. Remove all oil and grease from
the surface with a solvent in accordance with SSPC-SP1.
For optimal performance, use Commercial Blast Cleaning
in accordance with SSPC-SP6. Prime the area with a rust-
inhibitive primer the same day as cleaned.
Galvanized Steel:
Solvent clean new galvanized metal
in accordance with SSPC-SP1 to remove oil and grease
from the surface. Pre-treat with a phosphoric acid solution
or a commercially-available etching solution. Galvanized
metal that has been passivated with chromates or silicates
may require brush blasting in accordance with SSPC-SP16
to remove these treatments. Rusty galvanizing requires a
minimum of Hand Tool Cleaning in accordance with SSPC-
SP2. Prime the area the same day as cleaned.
Shop-Primed Steel: As there is potential for many forms
of contamination during storage and transport, a thorough
cleaning is always recommended for shop-primed surfaces.
Paint exposed areas, i.e., where shop primer is abraded,
with the same material as used for shop priming to comply
with SSPC-PA 1 for touching up shop-primed surfaces. Note:
Assess the integrity of the shop primer prior to application
of subsequent coatings. Review all coatings intended for
the project and conrm the compatibility between shop
and eld-applied coatings.
This information is provided “as is” and no representations or warranties, either express or implied, of merchantability, tness for a particular purpose or of any other
nature are made with respect to this information or to any product referred to in this information. For SDS or to consult with a Behr Paint Company representative,
call 1-800-854-0133 Ext. 2 (U.S.A. only). ©2020 Behr Process Corporation, Santa Ana, CA 92705 U.S.A.
*For as long as you reside in your home. See label for details.
Revised 5/2020
1 of 2

Summary of content (2 pages)