TDS
TECHNICAL DATA SHEET
This information is provided "as is" and no representations or warranties, either expressed or implied, of merchantability, tness for a particular purpose or of any other
nature are made with respect to this information or to any product referred to in this information. For MSDS or to consult with a Behr Certied Coatings Professional,
call 1-800-854-0133 Ext. 2 (U.S.A. only). ©2017 Behr Process Corporation Santa Ana, CA 92704 U.S.A.
Revised 1/2017
1 of 2
INTERIOR SEMIGLOSS ENAMEL PAINT
NO. 3750 ULTRA PURE WHITE®
PRODUCT INFORMATION
BEHR PREMIUM PLUS ULTRA® Interior Semi-Gloss Enamel Paint is a 100% acrylic paint and primer in one with advanced stain-blocking
formula that will change the way you paint. This product, featuring NANOGUARD® Technology, forms an extra-protective shell that
oers outstanding stain, scu, mar and antimicrobial-mildew resistance and an easy-to-clean, STAYS LOOKING NEW LONGER®
Finish with superior stain removal. This sophisticated color palette delivers exceptional hide and maximum moisture resistance.
RECOMMENDED USES:
Use on properly prepared, coated and uncoated, interior surfaces such as:
• Concrete • Concrete Block/CMU • Brick • Plaster
• Drywall/Gypsum Board • Wood • Ferrous Metals • Galvanized Steel
• Aluminum • Other Non-Ferrous Metal • Architectural Plastics
PRODUCT SPECIFICATIONS:
Tint Bases/Max Tint Load:
No. 3750 128 oz. / 2 oz.
No. 3754 120 oz. / 10 oz.
No. 3753 116 oz. / 14 oz.
Gloss: 45-55 @ 60°
Resin Type: 100% Acrylic
Weight per Gallon: 10.43 lbs.
% Solids by Volume: 37.45%
% Solids by Weight: 49.77%
VOC: <50 g/L
Flash Point: N/A
Viscosity: 95-105 KU
Recommended Film Thickness:
Wet: 6.4 mils / Dry: 2.4 mils @ 250 Sq. Ft./Gal.
Wet: 4.0 mils / Dry: 1.5 mils @ 400 Sq. Ft./Gal.
Coverage: 250-400 Sq. Ft./Gal. depending on application
method and substrate porosity. Does not include the loss of
material from spraying.
APPLICATION:
Brush: Nylon/polyester
Roller: 3/8" - 1/2" nap
Airless Spray: At packaged consistency
Tip: .015"- .019"
Filter: 60 mesh
Thinning: (If required) No more than 1/2 pint
of water per gallon.
Dry Time: @ 77° & 50% RH
Longer dry time may be required in cooler temperatures
and higher humidity.
To Touch: 1 hour
To Recoat: 2 hours
Full Cure: 4 weeks
SURFACE PREPARATION:
All surfaces must be clean, free of dust, chalk, oil, grease,
wax, polish, mold and mildew stains, loose and peeling
paint, rust, and all other foreign substances.
New Drywall: All drywall surfaces should be suciently
sanded smooth. Remove any remaining drywall dust prior
to priming. Allow all drywall compounds to be completely
dry prior to coating. Previously Painted Drywall: Remove
all loose and peeling paint and all other foreign substances.
Clean any dirt and grease by scrubbing the surface with
a detergent and water solution, followed by a thorough
rinsing with clean water. Set nails and ll holes, scratches,
and gouges with the appropriate spackling material.
Let dry completely and sand smooth. Remove all dust with
a wiping cloth. Fill all gaps with a 100% acrylic, siliconized,
paintable caulking, and allow to completely dry prior to
coating. Glossy Surfaces: For maximum adhesion,
sand the surface thoroughly before coating.
New Wood: Remove mill glaze with sandpaper.
Set nails and ll holes, scratches, and gouges with the
appropriate wood ller and let dry completely.
Remove all dust with a wiping cloth. Fill all gaps
with a 100% acrylic, siliconized, paintable caulking,
and allow to completely dry prior to coating.
Previously Painted Wood: Remove all loose and peeling
paint and all other foreign substances. Clean any dirt and
grease by scrubbing the surface with a detergent and water
solution, followed by a thorough rinsing with clean water.
Set nails and ll holes, scratches, and gouges with the
appropriate wood ller and let dry completely.
Remove all dust with a tack or wiping cloth.
Fill all gaps with a 100% acrylic, siliconized, paintable
caulking, and allow to completely dry prior to coating.
Glossy Surfaces: For maximum adhesion, sand the
surface thoroughly before coating.
Wood: WARNING! Sanding or scraping pressure treated
lumber may be hazardous; wear appropriate protection.
New Plaster: New plaster should be thoroughly dried
out and cured for a minimum of 30 days before painting.
When cured, clean using a mixed solution of one part
vinegar and one part water to remove eorescence and
neutralize. Previously Painted Plaster: Remove all
loose and peeling paint and all other foreign substances.
Clean any dirt and grease by scrubbing the surface with
a detergent and water solution, followed by a thorough
rinsing with clean water. Set nails and ll holes, scratches,
and gouges with the appropriate spackling material. Let dry
completely and sand smooth. Remove all dust with a tack
or wiping cloth. Fill all gaps with a 100% acrylic, siliconized,
paintable caulking, and allow to completely dry prior to
coating. Glossy Surfaces: For maximum adhesion,
sand the surface thoroughly before coating.
Stain-blocking: After priming, test for stain bleed-through
by applying the topcoat to a small section. If the stain bleeds
through the topcoat, apply a second coat of primer and
test again before top-coating the entire area. If bleeding
continues, a longer dry time of the primer may be needed
before top-coating.
Masonry: All masonry surfaces must be cured at least
30 days before painting. The pH must be 10.0 or lower prior
to coating. Smooth masonry may require an adequate
prole for adhesion. For all other smooth concrete, create a
prole using a product such as a muriatic acid etcher or with
mechanical means. Remove loose aggregate and debris.
Ferrous and Non-Ferrous Metal: The oil lm on new
COMPLIES WITH THE BELOW AS OF 1/1/2017
SCAQMD YES LEED v.4
†
YES
CARB YES MPI# 54
OTC YES MPI X-GREEN 54
LADCO YES GREENGUARD® YES
AIM YES CHPS YES
LEED v.3 (2009)
†
YES NAHB/ICC NGBS YES
This coating conforms to USDA regulatory requirements
for incidental food-contact materials intended for use on
surfaces not in direct contact with food, such as walls, oors
and ceilings.
†
Please visit www.usgbc.org/LEED for additional details.
GREENGUARD is a registered trademark of UL Company.