User Manual STUDIO CONDENSER MICROPHONE Dual-Diaphragm Studio Condenser Microphone
STUDIO CONDENSER MICROPHONE C-3 User Manual Important Safety Instructions Terminals marked with this symbol carry electrical current of sufficient magnitude to constitute risk of electric shock. Use only high-quality commercially-available speaker cables with ¼" TS plugs pre-installed. All other installation or modification should be performed only by qualified personnel.
STUDIO CONDENSER MICROPHONE C-3 User Manual 1. Power Supply Your condenser mic C-3 needs a phantom power supply (+48 V). If your C-3 is connected to a microphone preamp and supplied with phantom power, the LED on the microphone lights up. BEHRINGER assumes no liability for any damage caused by a defective phantom power supply. Always mute the sound reinforcement system before you switch on the phantom power supply. 2. Directivity Your C-3 is a large-diaphragm microphone featuring a double membrane.
STUDIO CONDENSER MICROPHONE C-3 User Manual 3. Low Cut-Filter and Signal Level Attenuation The low cut filter is activated via the left switch located at the front of your C-3 (switch position: left, ). Disruptive, low-frequency sounds such as subsonic noise, snapping and wind sounds can be filtered out. When the low cut filter is active, when recording a voice from a close distance, you get an almost entirely linear frequency response.
STUDIO CONDENSER MICROPHONE C-3 User Manual If necessary, you can bend the microphone out of its vertical position by using the hinge on the microphone stand. ◊ Please make sure to handle the microphone shaft with attention and care to avoid damaging the screw thread. In no situation should you ever apply excessive force. Of course, you can detach the C-3 from the stand mount adapter and attach it to a commercially available suspension mount. 5.
STUDIO CONDENSER MICROPHONE C-3 User Manual 0˚ 5 dB 45˚ 45˚ 10 dB 15 dB 20 dB 25 dB 90˚ 90˚ 135˚ 135˚ 180˚ Super Cardioid Figure 8 Omni Polar pattern dB 10 0 -10 -20 20 50 100 500 1000 Cardioid Low Cut Figure 3 -10 dB Omni Frequency response 200 2000 5000 10000 20000 Hz
STUDIO CONDENSER MICROPHONE C-3 User Manual 7. Specifications Transducer type condenser, 16 mm Polar pattern cardioid, figure 8, omni Connection gold-plated balanced XLR connector Open circuit sensitivity -40 dBV/pa (10 mV/pa) Frequency response 40 Hz - 18 kHz Max. SPL (< 0,5% THD @ 1 kHz) 142 dB Equivalent noise level 23 dBA (IEC 651) Dynamic range 119 dB Rated Impedance 350 Ω Mains Voltage/Fuse Supply voltage +48 V Supply current 7.