X32 MIDI Implementation (06 May 2014)
MIDI RX > SCENES
Whenever program change messages in the range 1-100 are received on MIDI CH01, thecorresponding
scene of the X32 internal show memory will be loaded.
This requires the following preconditions:
•
Setup / remote
– MIDI In/Out check marks must be set according to the connection on which MIDI input will be
accepted (via physical MIDI connectors on X32 or S16, or via XUF Card)
– MIDI In/Out check mark must be set for “Enable MIDI Scene Recall”
• Setup / global
– when tick mark “Con rm Pop-Ups” / “Scene Load” is active, also MIDI scene recalls will only
become active after manual con rmation
– if you prefer activating scenes via MIDI program changes immediately, un-check the
“Con rmPop-Ups” / “Scene Load” tick mark
• Scenes View / home
– valid scenes must be stored in the internal X32 show le. It is not possible to recall
emptyscenes.
– the scope of changes applied by a MIDI scene recall depends on the Scene Safes,
ParameterSafes and Channel Safes settings, same as with recalling the scene locally.
MIDI TX > SCENES
•
Every scene can be assigned one speci c MIDI command/event. Each time the scene is loaded
the MIDI command will be sent out once. Possible choices for MIDI commands/events to be found
on Scenes View/MIDI page:
– O > no message will be sent upon scene load
– Program Change > select the MIDI Channel and the Program Number (using knobs 4/5 at the
main display)
– Control Change > select the MIDI Channel, Controller number and value(using knobs 4-6 at
the main display)
– Note > select the MIDI Channel, Note number and velocity(using knobs 4-6 at the
maindisplay)
• will send out a Note On command directly followed by the same Note O command