User Guide
Table Of Contents
ENGLISH
EUROPOWER EP2000/EP4000 User Manual 
11
When using binding post connectors, please make sure that 
insulation on cables is not removed too high. Insert the naked 
part of the cable fully so that no metal is visible. Cable clamps 
must be isolated to avoid the possibility of electric shock. When 
running the amp in mono-bridged mode, always use the middle 
two binding post connectors, paying attention to correct polarity.
Caution
* 
If you notice naked cable endings on the binding post  
◊ 
connectors, do not power up the amp because of the risk  
of electric shock.
Connecting to the mains4.1.2 
Always connect your EUROPOWER amplier to the voltage 
specied on the rear of the device. Connecting the amp to an 
incorrect voltage can permanently damage your amp.
Before powering up the amplier, double-check all connections 
and fully lower the gain setting.
Audio connections4.2 
Various cables are needed for different types of applications. 
The following illustrations show the correct wiring. Always use 
high-grade cables.
When connecting a balanced input signal, please make sure 
◊ 
to exclusively use balanced cables for passing the signal 
further on. Otherwise, one single unbalanced cable can 
turn the entire signal unbalanced.
Fig. 4.3: XLR connectors
Fig. 4.4: ¼" TS connector
Fig. 4.5: ¼" TRS connector