User Manual EUROPORT EPA900 Ultra-Compact 900-Watt 8-Channel Portable PA System with Digital Effects and FBQ Feedback Detection
EUROPORT EPA900 User Manual Table of Contents Thank you........................................................................ 2 Important Safety Instructions....................................... 3 Legal Disclaimer.............................................................. 3 Limited Warranty............................................................ 3 1. Before You Get Started.............................................. 5 1.1 Shipment.............................................................
EUROPORT EPA900 User Manual Important Safety Instructions Terminals marked with this symbol carry electrical current of sufficient magnitude to constitute risk of electric shock. Use only high-quality commercially-available speaker cables with ¼" TS plugs pre-installed. All other installation or modification should be performed only by qualified personnel.
EUROPORT EPA900 User Manual (2) Subsequently, the product must be returned in its original shipping carton, together with the return authorization number to the address indicated by MUSIC Group. (3) Shipments without freight prepaid will not be accepted. § 4 Warranty Exclusions (1) This limited warranty does not cover consumable parts including, but not limited to, fuses and batteries.
EUROPORT EPA900 User Manual 1. Before You Get Started 1.3 Online registration 1.1 Shipment Please register your new BEHRINGER equipment right after your purchase by visiting http://behringer.com and read the terms and conditions of our warranty carefully. Your EPA900 was carefully packed at the factory, and the packaging was designed to protect the unit from rough handling.
EUROPORT EPA900 User Manual 2.2 Setup 3.1 Mono Channels (1-4) 1. Separate the three pieces of the PA unit as described in Chapter 2.1. Channels 1-4 are designed as mono channels and are used to connect microphones or mono line-level sources. The connectors are balanced to ensure high interference resistance. If possible, you should use balanced cable connectors to profit from the advantages of this type of connection. 2.
EUROPORT EPA900 User Manual 3.3 Channel strips 3.4 Additional connections Each channel strip is equipped with an equalizer section, an effects control, and one control each for signal routing and volume control. The EPA900 is equipped with additional inputs and outputs as well as a footswitch connector. TREBLE/BASS The equalizer section comprises these two controls. With the TREBLE control, you can modify the high frequencies, and with the BASS control the low frequencies.
EUROPORT EPA900 User Manual 3.6 Graphic equalizer PROGRAM (PUSH) The EPA900 is equipped with a 7-band graphic equalizer, which enables you to adapt the sound to the room conditions and your own ideas for the sound. The equalizer always processes the LEFT/MAIN and RIGHT/MAIN bus equally. You can turn the PROGRAM control knob to select an effects preset. Then press the knob to activate the selected effect. EFFECTS (LEVEL) The EFFECTS (LEVEL) control is used to adjust the effects signal volume. 3.
EUROPORT EPA900 User Manual POWER Switch Use the POWER switch to start up the unit. The POWER switch should be in the “Off” position when you connect the unit to the AC power supply. To disconnect the unit from the power supply, pull out the power plug. When starting up the unit, ensure that the power plug is easily accessible. ◊ Please note: Switching the POWER switch off does not completely disconnect the unit from the power supply.
EUROPORT EPA900 User Manual 4. Applications The EPA900 can be used for simple sound tasks, e.g., amplification of the presenter’s voice, playback sound, or karaoke applications, as well as for demanding tasks such as band amplification or stage monitor sound. A typical example of use as a sound system for music with live instruments and players is given below.
EUROPORT EPA900 User Manual 5. Specifications Inputs 1-4 Effects Type 4 x XLR, electronically balanced, 4 x ¼" TRS jack, electronically balanced Impedance approx. 2.2 kΩ , balanced, approx. 1.1 kΩ , unbalanced Input sensitivity -21 dBu @ PAD/OFF Max.
EUROPORT EPA900 User Manual 6. Effects Table EFFECT PRESETS No.
EUROPORT EPA900 User Manual FEDERAL COMMUNICATIONS COMMISSION COMPLIANCE INFORMATION EUROPORT EPA900 Responsible party name: MUSIC Group Services USA, Inc. Address: 18912 North Creek Parkway, Suite 200 Bothell, WA 98011, USA Phone/Fax No.