EURORACK UB1204-PRO/UB1204FX-PRO Users Manual Version 1.
EURORACK UB1204-PRO/UB1204FX-PRO IMPORTANT SAFETY INSTRUCTIONS DETAILED SAFETY INSTRUCTIONS: 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. CAUTION: To reduce the risk of electric shock, do not remove the top cover (or the rear section). No user serviceable parts inside; refer servicing to qualified personnel. 5) Do not use this apparatus near water. 6) Clean only with dry cloth. 7) Do not block any ventilation openings.
EURORACK UB1204-PRO/UB1204FX-PRO TABLE OF CONTENTS 1. INTRODUCTION ........................................................................................................ 4 1.1 General mixing console functions .................................................................................................................... 4 1.2 The users manual ........................................................................................................................................... 5 1.
EURORACK UB1204-PRO/UB1204FX-PRO 1. INTRODUCTION FOREWORD Dear Customer, Im sure youre one of those people who have devoted themselves body and soul to your chosen area and no doubt this has transformed you into an expert in your field! Well, for over 30 years, my passion has been music and electronics. This not only led me to establish BEHRINGER, but also enabled me to convey and share my enthusiasm with my employees.
EURORACK UB1204-PRO/UB1204FX-PRO 1.2 The users manual The users manual is designed to give you both an overview of the controls, as well as detailed information on how to use them. In order to help you understand the links between the controls, we have arranged them in groups according to their function. If you need to know more about specific issues, please visit our website at http://www.behringer.com, where youll find explanations of e.g. effects and dynamics applications.
EURORACK UB1204-PRO/UB1204FX-PRO 2.1.4 Routing switch, solo and channel fader Fig. 2.2: The equalizer of the input channels The upper (HI) and the lower band (LO) are shelving filters that increase or decrease all frequencies above or below their cut-off frequency. The cut-off frequencies of the upper and lower band are 12 kHz and 80 Hz respectively. The mid band is configured as a peak filter with a center frequency of 2.5 kHz. 2.1.3 Aux sends Fig. 2.4: Panorama and routing controls Fig. 2.
EURORACK UB1204-PRO/UB1204FX-PRO LEVEL For level matching, the stereo inputs feature a LEVEL switch which selects between +4 dBu and -10 dBV. At -10 dBV (home-recording level), the input is more sensitive than at +4 dBu (studio level). 2.3.2 Aux send connectors 1 and 2 2.2.2 Equalizer stereo channels The equalizer of the stereo channels is, of course, stereo. The filter characteristics and crossover frequencies are the same as those of the mono channels.
EURORACK UB1204-PRO/UB1204FX-PRO 2.3.4 Stereo aux return + If you connect a compressor or a noise gate after the 2-track output, the faders will probably not be able to create a satisfactory fade-out effect. 2.3.6 Level meter and monitoring Fig. 2.9: Stereo aux return controls STEREO AUX RETURN 1 STEREO AUX RETURN 1 is a stereo control which determines the level of the signal in the main mix. If STEREO AUX RETURN 1 is used as effects return, you can add the effects signal to any dry channel signal.
+ EURORACK UB1204-PRO/UB1204FX-PRO The peak meters of your EURORACK display the level virtually independent of frequency. A recording level of 0 dB is recommended for all signal types. 2.3.7 Alt 3-4 and main mix fader MODE (UB1204FX-PRO only) The MODE switch determines whether the channels SOLO switch operates as PFL (Pre Fader Listen) or as solo (Solo In Place). PFL To activate the PFL function, depress the MODE switch. The PFL function should, as a rule, be used for GAIN setting purposes.
EURORACK UB1204-PRO/UB1204FX-PRO 2.4.2 Voltage supply, phantom power and fuse 3. DIGITAL EFFECTS PROCESSOR Fig. 2.15: Voltage supply and fuse FUSE HOLDER The console is connected to the mains via the cable supplied which meets the required safety standards. Blown fuses must only be replaced by fuses of the same type and rating. IEC MAINS RECEPTACLE The mains connection is via a cable with IEC mains connector. An appropriate mains cable is supplied with the equipment.
EURORACK UB1204-PRO/UB1204FX-PRO 4. INSTALLATION 4.1 Rack mounting The packaging of your mixing console contains two 19" rack mount wings which can be installed on the side panels of the console. Before you can attach the rack mount wings to the mixing console, you need to remove the screws holding the left and right side panels. Use these screws to fasten the two wings onto the console, being careful to note that each wing fits a specific side.
EURORACK UB1204-PRO/UB1204FX-PRO 5. SPECIFICATIONS Mono inputs Microphone inputs (IMP Invisible Mic Preamp) Type XLR, electronically balanced, discrete input circuit Mic E.I.N. (20 Hz - 20 kHz) @ 0 W source resistance -134 dB / 135.7 dB A-weighted @ 50 W source resistance -131 dB / 133.3 dB A-weighted @ 150 W source resistance -129 dB / 130.5 dB A-weighted Frequency response <10 Hz - 150 kHz (-1 dB), <10 Hz - 200 kHz (-3 dB) Gain range Max.
EURORACK UB1204-PRO/UB1204FX-PRO 6. WARRANTY § 1 OTHER WARRANTY RIGHTS AND NATIONAL LAW 1. This warranty does not exclude or limit the buyers statutory rights provided by national law, in particular, any such rights against the seller that arise from a legally effective purchase contract. 2. The warranty regulations mentioned herein are applicable unless they constitute an infringement of national warranty law. 2.