User Manual MIDI FOOT CONTROLLER FCB1010 Ultra-Flexible MIDI Foot Controller with 2 Expression Pedals and MIDI Merge Function
MIDI FOOT CONTROLLER FCB1010 User Manual Table of Contents Important Safety Instructions....................................... 3 Legal Disclaimer.............................................................. 3 Limited Warranty............................................................ 3 1. Introduction................................................................ 4 1.1 Before you get started....................................................... 4 1.2 The user’s manual...............................
MIDI FOOT CONTROLLER FCB1010 User Manual Important Safety Instructions Terminals marked with this symbol carry electrical current of sufficient magnitude to constitute risk of electric shock. Use only high-quality professional speaker cables with ¼" TS or twist-locking plugs pre-installed. All other installation or modification should be performed only by qualified personnel.
MIDI FOOT CONTROLLER FCB1010 User Manual 1. Introduction Congratulations! With the BEHRINGER MIDI FOOT CONTROLLER FCB1010 you purchased an ultra-flexible controller unit for a wide range of applications, whether you are a guitarist, keyboard player or studio engineer: 10 BANKS with 10 PRESETS each and two fully user-programmable expression pedals will give you enough flexibility to manage your MIDI equipment.
MIDI FOOT CONTROLLER FCB1010 User Manual (1) FOOTSWITCHES 1 through 10/0. These keys are used for changing the presets, programming, entering values in programming mode and activating the DIRECT SELECT function (10/0 only). (2) UP/DOWN keys. These keys are used to navigate through different banks and programming layers. When in programming mode, use the UP key for ENTER (confirm) and the DOWN key for ESCAPE (cancel). (10) SERIAL NUMBER.
MIDI FOOT CONTROLLER FCB1010 User Manual 2.1.1 DIRECT SELECT deactivated Let’s assume you wish to select PRESET #1 from BANK #3... Step 1 Use the UP/DOWN switches to go to the BANK that contains the PRESET of your choice (here: BANK #3). As this example shows, the DIRECT SELECT feature gives you a faster access to BANKS and PRESETS than without this function. Which option to use is entirely up to you.
MIDI FOOT CONTROLLER FCB1010 User Manual 2.2.2 MIDI channel setting ◊ External equipment, for example guitar or bass amps, can be controlled by using SWITCH 1 and 2 outputs of the FCB1010. If the FCB1010 triggers this function, you should first check if the piece of equipment you are trying to control reacts to connection state (contact open or closed) or current feed (contact closed as long as the switch is depressed). BEHRINGER guitar and bass amps react to current feeds.
MIDI FOOT CONTROLLER FCB1010 User Manual Switch 1 2 3 4 5 6 7 8 9 10/0 MIDI Function PRG CHG 1 PRG CHG 2 PRG CHG 3 PRG CHG 4 PRG CHG 5 CNT 1 CNT 2 EXP A EXP B NOTE Action Program change command #1 Program change command #2 Program change command #3 Program change command #4 Program change command #5 Controller 1 Controller 2 Expression Pedal A Expression Pedal B Transmits a MIDI note Tab. 2.
MIDI FOOT CONTROLLER FCB1010 User Manual ◊ To program a MIDI function, you have to first activate it. Individual MIDI functions are activated by keeping the corresponding keys pressed for a few seconds. Active MIDI functions are indicated by a permanently lit footswitch LED. • Keep the corresponding footswitch (foot key 6 or 7) pressed for a few seconds to activate the controller you wish to edit. The controller is selected by pressing the key briefly again. The LED blinks. 2.4.
MIDI FOOT CONTROLLER FCB1010 User Manual The NOTE function will be particularly useful for so-called tap-tempo applications. Many of today’s multi-effects devices allow the user to enter the delay time by means of an on-board TAP button. The device measures the time between two TAP button presses and uses this interval to adjust the delay time. Often, this function can be remotely controlled via MIDI.
MIDI FOOT CONTROLLER FCB1010 User Manual 2.7 Data storage 2.7.2 Receiving SysEx dumps 2.7.1 Saving the FCB1010 memory with the help of SysEx dumps The FCB1010 allows you to transmit PRESETS in the form of system-exclusive data to a sequencer or other MIDI recorder. In this way, you can save your data or manage several MIDI set-ups (e.g. studio equipment, guitar equipment, etc.).
MIDI FOOT CONTROLLER FCB1010 User Manual Keep the respective footswitches pressed for roughly 2.5 sec while powering up your FCB1010. The displays reads “09” to “00” and the points are blinking. When the points are no longer shown, your FCB1010 has been reset to factory defaults and is ready for operation. 3.1 Basic setup Midi In 2.
MIDI FOOT CONTROLLER FCB1010 User Manual The effects processor is controlled via MIDI, while the SWITCH function toggles the amp. Thus, you’ll need no additional footswitch when you switch between the channels; instead, your entire setup is centrally controlled from the FCB1010. 3.3 Connections (General) Please use commercial-grade cables with phone plugs to connect the SWITCH outputs of your FCB1010 to your amplifier.
MIDI FOOT CONTROLLER FCB1010 User Manual Almost all devices have a list enclosed which shows the program change number versus preset number assignment. Some units even allow you to freely assign program change commands to preset numbers. Please see the corresponding user’s manual for detailed information. 4.2.4 Running status Since the MIDI standard uses a serial transmission format, i.e.
MIDI FOOT CONTROLLER FCB1010 User Manual FEDERAL COMMUNICATIONS COMMISSION COMPLIANCE INFORMATION MIDI FOOT CONTROLLER FCB1010 Responsible Party Name: MUSIC Group Services US Inc. Address: 18912 North Creek Parkway, Suite 200 Bothell, WA 98011, USA Phone/Fax No.
We Hear You