Pitch CV Calibration continued
Follow the procedure on the previous page to put the MODEL D into PITCH Calibration mode using SysEx.
Make sure that the preliminary procedures shown in section 5.1 have been followed, and the MODEL D front panel
controls and switches are set as directed.
Set the Digital Voltmeter to measure a range below 10 VDC.S
Locate the Test Points PITCH CV TP1 and TP2 on the bottom surface of the main PCB, as shown below.
Connect the positive probe of your Voltmeter to TP2.
Connect the negative probe of your Voltmeter to TP1 (ground).
DC Voltmeter
DC
Voltmeter
0.001