Calibration
Synthesizers and Samplers
MODEL D
page 13 of 23page 13 of 23
Connect the positive probe of your Voltmeter to TP2.
Press C4 on the external keyboard to set the Low calibration value.
Measure the output voltage. It should read -2.500 VDC.
If required, the output voltage can be adjusted to this value by pressing the following keys. The Pitch/CV output
adjustment resolution is about 2 mV
C3 = decrement coarse
D3 = decrement ne
E3 = increment ne
F3 = increment coarse
TIP: You can press and hold an increment or decrement key and (after a brief delay) the output adjustment will repeat
automatically until the key is released.
C4C#4 D4 E4C3C#3 D3 E3 F3
C4 Start Low Calibration. Target voltage is -2.500 Vdc
C#4 Exit Calibration Mode
D4 Start Zero Calibration. Target voltage is 0.000 Vdc
E4 Start High Calibration. Target voltage is 6.500 Vdc
C3 Decrement, Coarse
C#3 Save Calibration Settings
D3 Decrement, Fine
E3 Increment, Fine
Press to increment or decrement
or
Press and hold to automatically
increment or decrement
F3 Increment, Coarse
Low Calibration Adjustment