Calibration

Synthesizers and Samplers
MODEL D
page 13 of 23page 13 of 23
Connect the positive probe of your Voltmeter to TP2.
Press C4 on the external keyboard to set the Low calibration value.
Measure the output voltage. It should read -2.500 VDC.
If required, the output voltage can be adjusted to this value by pressing the following keys. The Pitch/CV output
adjustment resolution is about 2 mV
C3 = decrement coarse
D3 = decrement ne
E3 = increment ne
F3 = increment coarse
TIP: You can press and hold an increment or decrement key and (after a brief delay) the output adjustment will repeat
automatically until the key is released.
Low Calibration Adjustment