CLIP SIG User Manual XENYX QX1202 /QX1002 Premium 12/10-Input 2-Bus Mixer with XENYX Mic Preamps & Compressors, British EQs, KLARK TEKNIK Multi-FX Processor and USB/Audio Interface
XENYX QX1202USB/QX1002USB User Manual Table of Contents Thank you........................................................................ 2 Important Safety Instructions....................................... 3 Legal Disclaimer.............................................................. 3 Limited warranty............................................................. 3 1. Introduction................................................................ 4 1.1 General mixing console functions .................
XENYX QX1202USB/QX1002USB User Manual Important Safety Instructions Terminals marked with this symbol carry electrical current of sufficient magnitude to constitute risk of electric shock. Use only high-quality professional speaker cables with ¼" TS or twist-locking plugs pre-installed. All other installation or modification should be performed only by qualified personnel.
XENYX QX1202USB/QX1002USB User Manual 1. Introduction 1.1 General mixing console functions The XENYX Series represents a milestone in the development of mixing console technology. With the new XENYX microphone preamps including phantom power as an option, balanced line inputs and a powerful effects section, the mixing consoles in the XENYX Series are optimally equipped for live and studio applications.
XENYX QX1202USB/QX1002USB User Manual 1.2 Before you get started 2. Control Elements and Connectors 1.2.1 Shipment This chapter describes the various control elements of your mixing console. All controls, switches and connectors will be discussed in detail. Your mixing console was carefully packed in the factory to guarantee safe transport. Nevertheless, we recommend that you carefully examine the packaging and its contents for any signs of physical damage that may have occurred during transit. 2.
XENYX QX1202USB/QX1002USB User Manual GAIN PAN Use the GAIN control to adjust the input gain. This control should always be turned fully counterclockwise whenever you connect or disconnect a signal source to one of the inputs. The PAN control determines the position of the channel signal within the stereo image. This control features a constant-power characteristic, which means the signal is always maintained at a constant level, irrespective of position in the stereo panorama.
XENYX QX1202USB/QX1002USB User Manual BAL 2-TRACK INPUT The BAL(ANCE) control determines the levels of left and right input signals relative to each other before both signals are then routed to the main stereo mix bus. If a channel is operated in mono via the left line input, this control has the same function as the PAN control used in the mono channels. The 2-TRACK INPUTs are used to bring an external signal source (e.g. CD player, tape deck, etc.) into the console.
XENYX QX1202USB/QX1002USB User Manual LEVEL SETTING: USB CONNECTOR To correctly set the gains of the channels, first set the LEVEL controls of the input channels to their center positions. Then use the GAIN controls to increase the input amplification until signal peaks show 0 dB on the level meter. Connect your mixer to a computer using a standard USB cable. This enables a stereo signal to be sent to and from your mixer and computer.
XENYX QX1202USB/QX1002USB User Manual Presets List Reverb 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Modulation Small Chamber Mid Chamber Big Chamber Theater Small Room 1 Small Room 2 Mid Room 1 Mid Room 2 Large Room Small Hall Concert Hall Mid Hall Big Hall Ambient Hall Church Short Plate Mid Plate Long Plate Gold Plate Vint250Verb 1 Vint250Verb 2 Mid Spring Long Spring Gated Reverb Short Gated Reverb Mid Gated Reverb Long Gated Alive Reverse Short Reve
XENYX QX1202USB/QX1002USB User Manual 3. Applications 3.1 Recording studio HPS3000 C-1 B212D XM8500 V-AMP3 B2031A Keyboard Fig 3.
XENYX QX1202USB/QX1002USB User Manual 3.2 Live sound B215D Active Speakers Bass Guitar XM8500 DI100 F1320D Active Monitors L R CLIP SIG FX2000 Effects Processor Portable Digital Recorder MP3 Player Fig 3.2: Live performance with the QX1202USB The above diagram shows some typical connections for a live performance using the QX1202USB. Mono sources such as microphones and line-outs from guitar preamps or DI boxes can be connected to channels 1-4 via XLR or 1/4" cables.
XENYX QX1202USB/QX1002USB User Manual 4.2 Audio connections You will need a large number of cables for different applications. The illustrations below show how the connectors should be wired. Be sure to use only high-grade cables. Balanced ¼" TRS connector strain relief clamp sleeve ring tip Please use commercial RCA cables to connect the 2-Track inputs and outputs. You can, of course, also connect unbalanced equipment to the balanced inputs/ outputs.
XENYX QX1202USB/QX1002USB User Manual 5. Specifications QX1202USB QX1002USB Mono Inputs Microphone Inputs (XENYX Mic Preamp) Type XLR connector, balanced, discrete input circuit Mic E.I.N. (20 Hz - 20 kHz) @ 0 Ω source resistance -133 dB / -137 dB A-weighted @ 50 Ω source resistance -130 dB / -134 dB A-weighted @ 150 Ω source resistance -127 dB / -131 dB A-weighted <10 Hz - 150 kHz (-1 dB) Frequency response <10 Hz - 200 kHz (-3 dB) Gain range +10 dB to +60 dB Max.
XENYX QX1202USB/QX1002USB User Manual FEDERAL COMMUNICATIONS COMMISSION COMPLIANCE INFORMATION XENYX QX1202USB/QX1002USB Responsible Party Name: MUSIC Group Services US Inc. Address: 18912 North Creek Parkway, Suite 200 Bothell, WA 98011, USA Phone/Fax No.