6.1.7 Inputs Menu ! Base Band Levels / Change Over Inputs
Display−only screen.
Values of the inputs and deviation for the carriers are shown.
This mask may look different depending on the equipment operating mode.
Displaying VU−meter style bars, located on the right of numeric values, facilitates
the evaluation of the parameters.
The “Exchange
” mode may be “AUTOmatic” or “MANUAL” (in this case the
equipment must be controlled by the user). “ActiveCh
annel” shows the currently
active audio input. The “NoAudioLev
el(dB)” is the threshold below which
automatic exchange is activated after the audio remains so for the time indicated
in “NoAudio(s)
:
Inputs priority is managed by the “I
/ II/ III Input Select” list. A failure in the first (I)
audio input causes the switch to the second (II), a failure in the second one
causes the switch to the third (III). A failure in the third one restores the main
input and then no more changes. “Active Audio Alarm
: −> AES/EBU / MPX /
STEREO
” = “TRUE” enables the No Audio Alarm sending for each specific input.