ALARMS MENU
ALARMS MENU
56
6.1.13 Alarm Menu ! User Alarm Data / User Alarms Timers
Parameters of some alarms may be customized.
They are: Env
ironmental Temperature (C or F); RFTemperature (C or F); RFCur-
rent(A);
PSU
Temperature(C or F); PSU Current(A); Forward power(W) and Reflected
p
ower(W).
Forcing to “T” the value of “En
able” by pressing the encoder, the alarms will be acti-
vated depending on limits specified by “Max” and “Min” values.
It’s also possible to choose the criterion (Type) with which the limits will affect the
automatic algorithm: “UPPER” to have an alarm when the parameter will exceed
the max value; “LOWER” to have it below the minimum one; “INSIDE” to have an
alarm when the value is between max and minimum; “OUTSIDE” for the opposite.
A max value lower than the minimum one will exclude the alarm.
The left half mask works such as the previous one.
D
elay is the time frame before the alarm is considered valid. This parameter is expressed
in tenths of a second so that the value “120”, visible in the screen, means 12 seconds.
When a condition that could be an alarm is triggered, the related “Timer” starts. At the end
of the countdown, the alarm is validated and the flag “Al
arm” becomes “True”.