Manual

ACW4 ACW4
BEI Sensors SAS
Espace Européen de l’Entreprise
9, rue de Copenhague
B.P. 70044 Schiltigheim
F 67013 Strasbourg Cedex
Tél : +33 (0)3 88 20 80 80
Fax : +33 (0)3 88 20 87 87
Mail : info@beisensors.com
Web :
www.beisensors.com
PRELIMINARY - MAGNETIC CANopen ABSOLUTE SINGLE TURN MODULAR SENSORS, ACW4 RANGE PRELIMINARY - MAGNETIC CANopen ABSOLUTE SINGLE TURN MODULAR SENSORS, ACW4 RANGE
With its two-part design, the ACW4 CANopen absolute single-turn sensor offers maximum flexibility
when installing it.
A
pplication fields : agriculture, construction, forestry vehicles, medical, solar panels…
Robustness and excellent resistance to shocks / vibrations.
Standard IP 67 protection (IP69K option).
Ope
rating temperature range: -40°C to 85°C (-40..+125°C option).
Magnetic technology.
Universal supply 5 to 30Vdc – CANopen interface.
Available resolution up to 12 bits per revolution.
Also available : analog, PWM and SSI outputs.
Standard PVC + SUBD9 connector.
STANDARD ACW4 DIMENSION
Shaft system with magnet to be ordered separately (cf specific data-sheet).
MECHANICAL DATA
Material Macromelt OM638 Protection IP 67
Encoder weight (approx.) 0,100 kg Shocks (EN60068-2-27) 2000m.s
-2
(during 6 ms)
Operating temperature
- 40... + 85 °C (encoder T°) Vibrations (EN60068-2-6) 200m.s
-2
(55 … 2 000 Hz)
Storage temperature
- 40... + 85 °C
ADAPTATION POSSIBILTY
BEI Sensors distinguishes itself by its flexible approach and ability to react to customers needs, with us no limit exists; we shall always
try to supply you the product offering the best solution to your specifications.
Modified mechanics: Precision prototypes units, small and medium size. Units that will match themselves exactly to your mechanical
configuration or to your dimensional constraints.
Specific shaft system: for example with integrated coupling.
Send us your subset: we can integrate our encoder into your subset and return you the complete assembly with the guarantee of
an optimal mounting.
Connection / Cable assemblies: On the whole range of our sensors a wide selection of electrical connections are possible.
Changes possible without further notice 110411