Devicenet Industrial Datasheet
Version: 20130503
INDUSTRIAL INCLINOMETER
DEVICENET INTERFACE
MTBF Data
Failure Rate [FIT]
759
MTBF [Hours]
1,317,822
MTBF [Years]
150
The above mentioned data were calculated for electronics under the following conditions:
SNA: Non-mobile operation
Tu: 40°C - Mean component of ambient temperature
Zf: Continuous operation for 8760 h per year
Programmable Parameters
Resolution per 1°
The resolution parameter per 1° is used to program the desired
number of steps per 1°. The values 1, 10 and 100 can be
programmed. Default setting: 100.
Preset Value
The Preset value is the desired position value, which should be
reached at a certain physical position of the axis. The position
value is set to the desired process value by the preset parameter.
Moving Avarage-Filter
This filter can be used to adjust the bandwidth of measuring
values to minimize the influence of vibration. Factory Setting:
Moving average filter activated for 20 subsequent readouts.
Digital Recursive Filter
This filter can be used for weighting the last measured value with
the last previous value. This is useful to suppress sudden peaks in
the angle measurement.
Transmission rate
Adjustable: 125 kBaud, 250 kBaud, or 500 kBaud
Factory Setting: 125 KBaud
Address (MAC-ID)
Factory setting: Node ID = 63, Adjustable from 0 to 63
Programmable DeviceNet Transmission Modes
Polled Mode
Through an I/O-request telegram the connected host calls for the
current process value. The inclinometer reads the current
inclination value, calculates the eventually set-parameters and
sends back the obtained process value.
Cyclic Mode
The inclinometer transmits cyclically - without being called by the
host - the current process value. The cycle time can be
programmed in milliseconds for values between 1 ms and 65536
ms.
Change-of-State Mode
The inclinometer answers with current process value in case a
change of inclination is detected.