Analog Industrial Data Sheet
Version: 20130503
INDUSTRIAL INCLINOMETER
ANALOG & RS232 INTERFACE
Environmental Conditions
-40 °C to +85 °C / -40 °F to 185 °F
98 % Relative Humidity, Non-Condensing
IP 69K (With Appropriate Counter Connector), IP68, IP67
MTBF Data
759
1,317,822
150
The data mentioned above were calculated for inclinometer electronics under the following conditions:
SNA: Non-mobile operation
Tu: 40°C - Mean component of ambient temperature
Zf: Continuous operation for 8760 h per year
Default Factory Settings
Operational Mode
Continuous Mode
Resolution
0.01°
Output Transmission Rate
100 ms
Baud Rate
9600 Baud
Moving Average Filter
64
Angle Offset
0